VHDL - 与标准触发器不匹配

时间:2015-01-03 17:20:30

标签: vhdl

我试图用“VHDL”编写一些非常简单的东西。但我已经坚持了几个小时,我无法找到一种方法让它发挥作用。

我试图找到一种方法在不同的过程中使用相同的信号或将它们组合成一个过程。 在不同的过程中使用信号是不可能的,如果我将它们组合成一个过程,我会收到错误“与标准触发器不匹配”。我希望这里有人可以帮助我,并说我如何解决这个问题。

示例代码;

process(scan_ready,rc5_ready) 
variable welkescan : std_logic_vector(1 downto 0);
begin
    if (scan_ready' event and scan_ready = '0') and not((rc5_ready' event and rc5_ready = '0')) then
      welkescan := "01";
      visualisatiegebruikt <= "0001";
      visualisatiecode <= scan_code;
    elsif (rc5_ready' event and rc5_ready = '0') and not((scan_ready' event and scan_ready = '0')) then
      welkescan := "10";
      visualisatiegebruikt <= "0010";
      visualisatiecode <= scan_con;
    else
      welkescan := "00";
    end if;

    if ((welkescan = "01" and scan_code = "01110010") or (welkescan = "10" and scan_code = "00100001")) and (pwm_on /= "11111100") then
      pwm_on <= pwm_on +  28;
      visualisatiepwm <= visualisatiepwm + "0001";
    elsif ((welkescan = "01" and scan_code = "01110101") or (welkescan = "10" and scan_code = "00100000")) and (pwm_on /= "00000000") then
      pwm_on <= pwm_on - 28;
      visualisatiepwm <= visualisatiepwm - "0001";
    end if;
end process;    

我还尝试了代码示例:

process(scan_ready)
begin
    if scan_ready' event and scan_ready = '0' then
        visualisatie <= "0001"; -- 1 op display => toetsenbord
        scanwaarde(3 downto 0) <= scan_code(3 downto 0);
        scanwaarde(7 downto 4) <= scan_code(7 downto 4);
        if scan_code = "01110010" and pwmaansturen /= "11111100" then 
            pwmaansturen <= pwmaansturen +  28;
            visualisatiepwm <= visualisatie + "0001";
        elsif scan_code = "01110101" and pwmaansturen /= "00000000" then
            pwmaansturen <= pwmaansturen - 28;
            visualisatiepwm <= visualisatie - "0001";
        elsif scan_code = "01110100" then
            pwmaansturen <= "11111100";
            visualisatiepwm <= "1001";
        elsif scan_code = "01101011" then
            pwmaansturen <= "00000000";
            visualisatiepwm <= "0000";
        end if;
    end if;
end process;    

process(rc5_ready) 
    begin

    if rc5_ready' event and rc5_ready = '0' then
        visualisatie <= "0010"; -- 2 op display => afstandsbediening
        scanwaarde(3 downto 0) <= scan_con(3 downto 0);
        scanwaarde(7 downto 4) <= scan_con(7 downto 4);
        if scan_con = "00100001" and pwmaansturen /= "11111100" then 
            pwmaansturen <= pwmaansturen + 28;
            visualisatiepwm <= visualisatie + "0001";
        elsif scan_con = "00100000" and pwmaansturen /= "00000000" then 
            pwmaansturen <= pwmaansturen - 28;
            visualisatiepwm <= visualisatie - "0001";
        elsif scan_con = "00010110" then
            pwmaansturen <= "11111100";
            visualisatiepwm <= "1001";
        elsif scan_con = "00010111" then
            pwmaansturen <= "00000000";
            visualisatiepwm <= "0000";
        end if;
    end if;
end process;

我希望有人可以帮助我。 问候。

1 个答案:

答案 0 :(得分:1)

此代码有多个问题。

首先,所有这些代码都不可综合。使用用于仿真的硬件描述语言,对于真实的硬件描述和综合,要求设计人员使用多种编码模式,以便工具可以将其转换为网表和门。

不可合成代码的主要原因:

  1. 你不能和两个时钟事件。什么时候应该这样?
  2. 您无法使用not(clock'event ...)
  3. 其他提示和问题:

    • 你为什么使用下降边缘事件?
      常见设计使用上升沿时钟事件。并非每个平台都内置支持下降沿触发器。
    • scan_readyrc5_ready两个时钟信号?
      • 如果是:您构建了一个具有多个时钟域的设计,这需要适当的时钟同步电路和其他人员来消除您设计中的多个故障。
      • 如果否:不建议在非时钟信号上使用上升沿/下降沿检测。这意味着您的设计与系统时钟异步,这也需要跨时钟电路。