我们已将一些后端数据表从网络驱动器(mbd文件)移到SQL Server数据库上。事情通常很有效,但如果员工通过VPN访问事物(这会减慢很多事情),那么当我们运行检索大量数据的报告时,我们会收到连接错误。我的猜测是我需要将超时设置为更大的值,我做了一些研究,似乎我需要设置commandtimeout(或者可能是查询超时?)。
下面是我们用来将SQL Server表/视图从SQL Server后端连接到Access前端的VBA代码。我是对的,我可能需要指定一个命令超时?在这里我们会添加commandtimeout(或其他超时)值吗?
Public Sub CreateSQLLinkedTable(strSourceTableName As String, strNewTableName As String)
'************************************************************************************
'* Create a linked table in the current database from a table in a different SQL Server file.
'* In: *
'* strNewTableName - name of linked table to create *
'* strSourceTableName - name of table in database *
'************************************************************************************
Setup:
Dim tdf As TableDef
Dim strConnect As String, strMsg As String
Dim myDB As Database
' set database vars
Set myDB = CurrentDb
Set tdf = myDB.CreateTableDef(strNewTableName)
MakeConnections:
On Error GoTo OnError
' turn system warnings off
DoCmd.SetWarnings False
' define connect string and source table
' We do not need to specify the username (Uid) and password (Pwd) in this connection
' string, because that information is already cached from the connection to the SQL
' Projects database that we created in CheckSQLConnection() that was run to check connection
' to the database. So here we can have a connection string without the Uid and Pwd.
With tdf
.Connect = "ODBC;Driver={SQL Server};" & _
"server=" & myServer & ";" & _
"database=" & mySQLDB & ";"
.SourceTableName = strSourceTableName
End With
' execute appending the table
myDB.TableDefs.Append tdf
' turn system warnings back on
DoCmd.SetWarnings True
ExitProgram:
' this block of code will run if there are no errors
Exit Sub
OnError:
' this block of code runs if there is an error, per On Error assignment above
' display error message with details
MsgBox "There was an error connecting to the SQL Server data source Projects. Error = " & err & ", Description: " & err.Description
'exit Projects
Call CloseFormsAndQuit
End Sub
答案 0 :(得分:2)
有一个ODBC超时属性。在设计视图中打开查询,然后转到属性以查看它。当前数据库属性页面上还有一个(ODBC)查询超时。您也可以通过编程方式设置它:
Dim objDB As DAO.Database
Set objDB = CurrentDb()
objDB.QueryTimeout = 120
http://www.geeksengine.com/article/how-to-change-timeout-value-for-access-sql.html
另请检查服务器配置。服务器端有一个查询超时。