我正在使用2个级联移位寄存器对SSD显示进行编码。我正在使用mikroC for PIC编译器。我可以使用我的代码Static Display of 4 Numbers
显示最多4位数的静态数字序列 #define SHIFT_CLOCK PORTB.F1 //Clock Connection of 74HC595 SSD Driver
#define SHIFT_LATCH PORTB.F3 //Latch Connection of 74HC595 SSD Driver
#define SHIFT_DATA PORTB.F2 //Data Connection of 74HC595 SSD Driver
char array4[4] = {6, 91, 79, 102}; //Display 1234 on SSD
char digit[4] = {0xFE, 0xFD, 0xFB, 0xF7}; //Switch on the SSD digits one by one
char i,j,temp,flag1,flag2;
void InitTimer0()
{
OPTION_REG = 0x86;
TMR0 = 6;
INTCON = 0xA0;
}
void latch595()
{
SHIFT_LATCH = 1;
Delay_us(1);
SHIFT_LATCH = 0;
}
void shiftdata595(unsigned char _shiftdata)
{
int i;
unsigned char temp;
temp = _shiftdata;
i=8;
while (i>0)
{
if (temp.F7==0)
{
SHIFT_DATA = 0;
}
else
{
SHIFT_DATA = 1;
}
temp = temp<<1;
SHIFT_CLOCK = 1;
SHIFT_CLOCK = 0;
i--;
}
}
void Interrupt()
{
if (TMR0IF_bit)
{
TMR0IF_bit = 0;
TMR0 = 6;
flag1 = 1;
flag2 = 1;
}
}
void main()
{
TRISB = 0;
TRISC.F1 = 1;
InitTimer0();
while (1)
{
if (PORTC.F1==0)
{
if (flag2==1)
{
shiftdata595(digit[i]);
i++;
if(i==4)
{
i=0;
}
if (flag1==1)
{
shiftdata595(array4[j]);
latch595();
j++;
if (j==4)
{
j=0;
}
}
}
}
else if(PORTC.F1==1)
{
shiftdata595(0);
shiftdata595(0);
latch595();
}
}
}
如果我向array4 []添加更多数字,比如高达9,我需要按顺序向左滚动数字。 我尝试通过
移动数组temp = array4[0];
for (n=1; n<8; n++)
{
array4[j-1] = array[j];
}
array[9] = temp;
我希望这段代码能够移动数组并且显示屏会滚动,但我得到的只是混乱的显示。如果我添加延迟,我可以看到数字显示但没有滚动。
基本算法是否有问题,还是可以通过修改代码来使用?
答案 0 :(得分:0)
我确实弄清了我的代码问题。循环错了。我在级联模式下使用两个74HC595。一个控制数字(共阴极),另一个控制段。由于只有一条数据线将信息传递给数字和段,因此需要协调数字推进的时间和段。整个问题是我不必要地专注于协调的时序部分,而是我应该集中在循环条件上,这会使段前进,然后左移数组。
朋友指出,我需要在一张纸上写下每个循环的数据值,这样才能解决问题。我没有像array4 [8]或array4 [10]那样手动给出循环数组的长度,而是使用了sizeof()函数,然后在循环的前四次迭代之后,左移了数组一个位置。现在滚动工作完美。
以下是更新后的工作代码
shiftdata595(array4[tmp7]);
latch595();
Delay_ms(32);
tmp7++;
if (tmp7>=4)
{
tmp7=0;
tmp1 = sizeof(array4)/sizeof(array4[0]);
tmp2 = array4[0];
for (n=1;n<tmp1;n++)
{
array4[n-1] = array4[n];
}
array4[tmp1-1] = tmp2;
}