我正在尝试设置BLE温度计的Interval属性,并遇到一些问题。
我已经测试过设置属性,例如NetworkManager中的WimaxEnabled属性:
$ gdbus call --system --dest org.freedesktop.NetworkManager \
--object-path /org/freedesktop/NetworkManager \
--method org.freedesktop.DBus.Properties.Set \
"org.freedesktop.NetworkManager" "WimaxEnabled" "<boolean false>"
()
$ gdbus call --system --dest org.freedesktop.NetworkManager \
--object-path /org/freedesktop/NetworkManager \
--method org.freedesktop.DBus.Properties.Set \
"org.freedesktop.NetworkManager" "WimaxEnabled" "<boolean true>"
()
我可以验证这些功能确实像宣传的那样工作。当我尝试设置Interval的属性时,事情变得奇怪了。我可以毫无问题地清除Interval
$bgdbus call --system --dest org.bluez \
--object-path /org/bluez/hci0/dev_00_07_80_A6_3A_CA \
--method org.freedesktop.DBus.Properties.Set \
"org.bluez.Thermometer1" "Interval" "<uint16 0>"
()
但尝试将间隔设置为任何其他值会导致错误。我已经尝试了每个可能的uint16值,结果相同。
$ gdbus call --system --dest org.bluez \
--object-path /org/bluez/hci0/dev_00_07_80_A6_3A_CA \
--method org.freedesktop.DBus.Properties.Set \
"org.bluez.Thermometer1" "Interval" "<uint16 1>"
Error: GDBus.Error:org.bluez.Error.InvalidArguments: Invalid arguments in method call
(According to introspection data, you need to pass 'ssv')
Interval属性设置为读/写
$ gdbus introspect --system --dest org.bluez --object-path /org/bluez/hci0/dev_00_07_80_A6_3A_CA
node /org/bluez/hci0/dev_00_07_80_A6_3A_CA {
interface org.freedesktop.DBus.Introspectable {
methods:
Introspect(out s xml);
signals:
properties:
};
interface org.bluez.Device1 {
methods:
Disconnect();
Connect();
ConnectProfile(in s UUID);
DisconnectProfile(in s UUID);
Pair();
CancelPairing();
signals:
properties:
readonly s Address = '00:07:80:A6:3A:CA';
readonly s Name = 'test';
readwrite s Alias = 'test';
readonly u Class;
readonly q Appearance = 24585;
readonly s Icon;
readonly b Paired = true;
readwrite b Trusted = false;
readwrite b Blocked = false;
readonly b LegacyPairing = false;
readonly n RSSI;
readonly b Connected = true;
readonly as UUIDs = ['00001809-0000-1000-8000-00805f9b34fb'];
readonly s Modalias;
readonly o Adapter = '/org/bluez/hci0';
};
interface org.freedesktop.DBus.Properties {
methods:
Get(in s interface,
in s name,
out v value);
Set(in s interface,
in s name,
in v value);
GetAll(in s interface,
out a{sv} properties);
signals:
PropertiesChanged(s interface,
a{sv} changed_properties,
as invalidated_properties);
properties:
};
interface org.bluez.Thermometer1 {
methods:
signals:
properties:
readonly b Intermediate = false;
readwrite q Interval = 0;
readonly q Maximum = 0;
readonly q Minimum = 0;
};
};
我还编写了一个C程序来执行此操作并获得完全相同的结果,0个工作,其他每个值都失败。有人见过这个吗?有任何建议吗?
编辑:
总是会发生,我发布后很快意识到这个问题。我认为最小和最大属性是Interval的范围。由于两者都设置为0,我显然无法将Interval属性设置为0以外的任何值。