我正在尝试与ECUsim 2000进行通信,这是OBD-ll ECU模拟器(link)。然而,我总是从设备收到的回复就像“??”要么 ”?” (当我运行TouchScan或OBD Auto Doctor等程序时,他们成功读取数据,因此设备工作正常)。我正在通过
向C#发送命令serialPort1.Write("010D\r")
我在SerialPort的DataReceived事件中接收信号为
message = "Data Received: " + serialPort1.ReadExisting();
this.Invoke(new EventHandler(displayText));
我现在不知道我错过了什么。这是完整的源代码
private void Form1_Load(object sender, EventArgs e)
{
serialPort1.PortName = "COM3";
serialPort1.BaudRate = 115200;
serialPort1.Parity = System.IO.Ports.Parity.None;
serialPort1.StopBits = System.IO.Ports.StopBits.One;
serialPort1.DataBits = 8;
serialPort1.Handshake = System.IO.Ports.Handshake.None;
serialPort1.Open();
}
private void button1_Click(object sender, EventArgs e)
{
if (serialPort1.IsOpen)
{
serialPort1.Write("010D\r");
}
}
private void displayText(object sender, EventArgs e)
{
textBox1.AppendText(message + "\n");
}
private void serialPort1_DataReceived(object sender, System.IO.Ports.SerialDataReceivedEventArgs e)
{
message = "Data Received: " + serialPort1.ReadExisting();
this.Invoke(new EventHandler(displayText));
}
ECUsim 2000的默认通讯设置
波特率:115200 数据位:8 平价:没有 停止位:1
协议是ISO 15765-4,设备上有两个开关,协议属性为CAN ID 29/11位,CAN波特率为500 kbps / 250kbps。也许,这个问题与这些问题有关,因此没有适当的沟通方式。
另一个问题 - >有没有办法在串行通信中设置协议(如ISO 15765-4)?
答案 0 :(得分:0)
有两个问题与给出的代码有关。
1)ECUsim 2000上有两个连接器。其中一个是B型USB端口,另一个是诊断链路连接器(DLC)。如果想通过B型USB端口连接到设备,波特率为:115200。如果使用DLC,波特率最可能是9600或38400.这里,通过扫描工具连接,因此(对于我的情况)波特率38400对我有用。
2)如评论中所述,为了获取数据,必须使用SerialPort的Read()
方法。它可以用作以下代码:
int buffSize = 1024;
bool cont = true;
int count = 0;
byte[] bff = new byte[buffSize];
string returnVal = string.Empty;
count = serialPort1.Read(bff, 0, buffSize);
returnVal += System.Text.Encoding.Default.GetString(bff, 0, count);