我试图从传感器读取数据。传感器控制器正在使用db9 header(com1),因为我将使用com1,我使用db9到usb转换器并获得com 11.
我有读取和写入串口的程序,当我使用com1时它可以工作,但是当我更改为com 11时,程序无法打开com,因为它到达ERROR_FILE_NOT_FOUND
这是我的串口编程程序:
Serial::Serial(char *portName)
{
this->connected = false;
wchar_t wcPort[64];
size_t convertedChars = 0;
mbstowcs_s(&convertedChars, wcPort, strlen(portName), portName, _TRUNCATE);
this->hSerial = CreateFile(wcPort,
GENERIC_READ | GENERIC_WRITE,
0,
NULL,
OPEN_EXISTING,
FILE_ATTRIBUTE_NORMAL,
0);
//Check if the connection was successfull
if(this->hSerial==INVALID_HANDLE_VALUE)
{
//If not success full display an Error
if(GetLastError()==ERROR_FILE_NOT_FOUND){
//Print Error if neccessary
printf("ERROR: Handle was not attached. Reason: %s not available.\n", portName);
}
else
{
printf("ERROR!!!");
}
}
else
{
DCB dcbSerialParams = {0};
if (!GetCommState(this->hSerial, &dcbSerialParams))
{
printf("failed to get current serial parameters!");
}
else
{
dcbSerialParams.BaudRate=CBR_38400;
dcbSerialParams.ByteSize=8;
dcbSerialParams.StopBits=ONESTOPBIT;
dcbSerialParams.Parity=NOPARITY;
dcbSerialParams.fOutX=TRUE;
dcbSerialParams.fInX=TRUE;
if(!SetCommState(hSerial, &dcbSerialParams))
{
printf("ALERT: Could not set Serial Port parameters");
}
else
{
this->connected = true;
}
}
}
}
是因为软件/程序还是硬件问题?
当我尝试使用超级终端时,它可以读写com 11。
答案 0 :(得分:3)
要打开编号为10或更高的COM端口,您需要在名称前添加\\.\
。
现在,在C中,你必须逃避所有这些反斜杠。因此,您需要打开的端口是"\\\\.\\COM11"
。