我正在用C#(4.0 Framework)开发CMS应用程序,它连接到远程服务器上的MySQL数据库(5.0.95) 通过MySQL Connector(6.5.4)。
我在执行查询时遇到问题。
e.g。 我的连接字符串:
"Server=" + Options.DbServer + ";Database="+ Options.Database +";Uid=" + Options.DbUser + ";Pwd=" + Options.DbPassword + ";CharSet=utf8; Connect Timeout=30;";
我有静态类来管理数据库相关的东西,我有私人成员_connection。
private static MySqlConnection _connection;
public static MySqlConnection Connection
{
get
{
if (_connection.State != ConnectionState.Open)
_connection.Open();
return _connection;
}
set { _connection = value; }
}
这是初始化连接的方法:
public static bool Init(string cs)
{
_connection = new MySqlConnection(cs);
MySqlCommand command = new MySqlCommand("SET NAMES utf8", Connection);
command.ExecuteNonQuery();
return true;
}
这是我得到例外的方法:
public static bool InsertRecord(MySqlCommand command)
{
command.Connection = Connection;
if(command.ExecuteNonQuery() > 0)
return true;
return false;
}
command.ExecuteNonQuery()
抛出异常:在命令执行期间遇到致命错误。
这是堆栈跟踪......
MySql.Data.MySqlClient.MySqlException was unhandled
Message=Fatal error encountered during command execution.
Source=MySql.Data
ErrorCode=-2147467259
Number=0
StackTrace:
at MySql.Data.MySqlClient.MySqlCommand.ExecuteReader(CommandBehavior behavior)
at MySql.Data.MySqlClient.MySqlCommand.ExecuteNonQuery()
at CMS.Database.InsertRecord(MySqlCommand command) in C:\_myStuff\VS2010\CMS\CMS\Database.cs:line 95
at CMS.frmAddItem.btnDo_Click(Object sender, EventArgs e) in C:\_myStuff\VS2010\CMS\CMS\frmAddItem.cs:line 138
at System.Windows.Forms.Control.OnClick(EventArgs e)
at System.Windows.Forms.Button.OnClick(EventArgs e)
at System.Windows.Forms.Button.OnMouseUp(MouseEventArgs mevent)
at System.Windows.Forms.Control.WmMouseUp(Message& m, MouseButtons button, Int32 clicks)
at System.Windows.Forms.Control.WndProc(Message& m)
at System.Windows.Forms.ButtonBase.WndProc(Message& m)
at System.Windows.Forms.Button.WndProc(Message& m)
at System.Windows.Forms.Control.ControlNativeWindow.OnMessage(Message& m)
at System.Windows.Forms.Control.ControlNativeWindow.WndProc(Message& m)
at System.Windows.Forms.NativeWindow.DebuggableCallback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam)
at System.Windows.Forms.UnsafeNativeMethods.DispatchMessageW(MSG& msg)
at System.Windows.Forms.Application.ComponentManager.System.Windows.Forms.UnsafeNativeMethods.IMsoComponentManager.FPushMessageLoop(IntPtr dwComponentID, Int32 reason, Int32 pvLoopData)
at System.Windows.Forms.Application.ThreadContext.RunMessageLoopInner(Int32 reason, ApplicationContext context)
at System.Windows.Forms.Application.ThreadContext.RunMessageLoop(Int32 reason, ApplicationContext context)
at System.Windows.Forms.Application.RunDialog(Form form)
at System.Windows.Forms.Form.ShowDialog(IWin32Window owner)
at System.Windows.Forms.Form.ShowDialog()
at CMS.frmMain.btnNovi_Click(Object sender, EventArgs e) in C:\_myStuff\VS2010\CMS\CMS\frmMain.cs:line 381
at System.Windows.Forms.Control.OnClick(EventArgs e)
at System.Windows.Forms.Button.OnClick(EventArgs e)
at System.Windows.Forms.Button.OnMouseUp(MouseEventArgs mevent)
at System.Windows.Forms.Control.WmMouseUp(Message& m, MouseButtons button, Int32 clicks)
at System.Windows.Forms.Control.WndProc(Message& m)
at System.Windows.Forms.ButtonBase.WndProc(Message& m)
at System.Windows.Forms.Button.WndProc(Message& m)
at System.Windows.Forms.Control.ControlNativeWindow.OnMessage(Message& m)
at System.Windows.Forms.Control.ControlNativeWindow.WndProc(Message& m)
at System.Windows.Forms.NativeWindow.DebuggableCallback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam)
at System.Windows.Forms.UnsafeNativeMethods.DispatchMessageW(MSG& msg)
at System.Windows.Forms.Application.ComponentManager.System.Windows.Forms.UnsafeNativeMethods.IMsoComponentManager.FPushMessageLoop(IntPtr dwComponentID, Int32 reason, Int32 pvLoopData)
at System.Windows.Forms.Application.ThreadContext.RunMessageLoopInner(Int32 reason, ApplicationContext context)
at System.Windows.Forms.Application.ThreadContext.RunMessageLoop(Int32 reason, ApplicationContext context)
at System.Windows.Forms.Application.RunDialog(Form form)
at System.Windows.Forms.Form.ShowDialog(IWin32Window owner)
at System.Windows.Forms.Form.ShowDialog()
at CMS.frmLogin.DoLogin() in C:\_myStuff\VS2010\CMS\CMS\frmLogin.cs:line 55
at CMS.frmLogin.button2_Click(Object sender, EventArgs e) in C:\_myStuff\VS2010\CMS\CMS\frmLogin.cs:line 31
at System.Windows.Forms.Control.OnClick(EventArgs e)
at System.Windows.Forms.Button.OnClick(EventArgs e)
at System.Windows.Forms.Button.OnMouseUp(MouseEventArgs mevent)
at System.Windows.Forms.Control.WmMouseUp(Message& m, MouseButtons button, Int32 clicks)
at System.Windows.Forms.Control.WndProc(Message& m)
at System.Windows.Forms.ButtonBase.WndProc(Message& m)
at System.Windows.Forms.Button.WndProc(Message& m)
at System.Windows.Forms.Control.ControlNativeWindow.OnMessage(Message& m)
at System.Windows.Forms.Control.ControlNativeWindow.WndProc(Message& m)
at System.Windows.Forms.NativeWindow.DebuggableCallback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam)
at System.Windows.Forms.UnsafeNativeMethods.DispatchMessageW(MSG& msg)
at System.Windows.Forms.Application.ComponentManager.System.Windows.Forms.UnsafeNativeMethods.IMsoComponentManager.FPushMessageLoop(IntPtr dwComponentID, Int32 reason, Int32 pvLoopData)
at System.Windows.Forms.Application.ThreadContext.RunMessageLoopInner(Int32 reason, ApplicationContext context)
at System.Windows.Forms.Application.ThreadContext.RunMessageLoop(Int32 reason, ApplicationContext context)
at System.Windows.Forms.Application.Run(Form mainForm)
at CMS.Program.Main() in C:\_myStuff\VS2010\CMS\CMS\Program.cs:line 18
at System.AppDomain._nExecuteAssembly(RuntimeAssembly assembly, String[] args)
at System.AppDomain.ExecuteAssembly(String assemblyFile, Evidence assemblySecurity, String[] args)
at Microsoft.VisualStudio.HostingProcess.HostProc.RunUsersAssembly()
at System.Threading.ThreadHelper.ThreadStart_Context(Object state)
at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state, Boolean ignoreSyncCtx)
at System.Threading.ExecutionContext.Run(ExecutionContext executionContext, ContextCallback callback, Object state)
at System.Threading.ThreadHelper.ThreadStart()
InnerException: MySql.Data.MySqlClient.MySqlException
Message=Fatal error encountered attempting to read the resultset.
Source=MySql.Data
ErrorCode=-2147467259
Number=0
StackTrace:
at MySql.Data.MySqlClient.MySqlDataReader.NextResult()
at MySql.Data.MySqlClient.MySqlCommand.ExecuteReader(CommandBehavior behavior)
InnerException: MySql.Data.MySqlClient.MySqlException
Message=Reading from the stream has failed.
Source=MySql.Data
ErrorCode=-2147467259
Number=0
StackTrace:
at MySql.Data.MySqlClient.MySqlStream.LoadPacket()
at MySql.Data.MySqlClient.MySqlStream.ReadPacket()
at MySql.Data.MySqlClient.NativeDriver.GetResult(Int32& affectedRow, Int32& insertedId)
at MySql.Data.MySqlClient.Driver.GetResult(Int32 statementId, Int32& affectedRows, Int32& insertedId)
at MySql.Data.MySqlClient.Driver.NextResult(Int32 statementId, Boolean force)
at MySql.Data.MySqlClient.MySqlDataReader.NextResult()
InnerException: System.IO.EndOfStreamException
Message=Attempted to read past the end of the stream.
Source=MySql.Data
StackTrace:
at MySql.Data.MySqlClient.MySqlStream.ReadFully(Stream stream, Byte[] buffer, Int32 offset, Int32 count)
at MySql.Data.MySqlClient.MySqlStream.LoadPacket()
InnerException:
有什么建议吗?
答案 0 :(得分:6)
我注意到你打开了连接,但是当你完成它们时你不会关闭它们。我更喜欢在需要时打开连接的方法,而不是在它们尚未打开时打开连接。它们可能是陈旧的。
缓存连接字符串,但不缓存连接本身。
public static string ConnectionString {get;set;}
public static bool InsertRecord(sql)
{
bool success = false;
using (var con = new Connection(ConnectionString)){
var command = new SqlCommand(sql,con);
success = (command.ExecuteNonQuery() > 0);
}
return success;
}
当不再需要资源时,应释放资源。
答案 1 :(得分:3)
我建议您查看有关此问题的this错误报告。
答案 2 :(得分:1)
MySQL在不同级别使用一堆不同的超时变量。
建立连接时 - >的 connect_timeout 强>
当服务器等待空闲以便发送另一个查询时 - >的 WAIT_TIMEOUT 强>
如果正在读取查询或正在发送结果集 - > net_read_timeout 和 net_write_timeout
net_write_timeout和net_read_timeout都是会话级变量,因此当您知道查询会很麻烦时,您可以根据连接更改它们,因此它不会影响服务器的其余部分。 (作为解决方法)
但首先,您应该通过执行以下操作来检查服务器上每个超时值的默认值:
show variables like '%timeout%'
您还应该查看您正在插入的命令,看看它是否可以简化,或者介绍较小的更新。
答案 3 :(得分:0)
添加buildscript {
repositories {
maven { url "file:///reporoot/" }
}
dependencies {
classpath 'com.bmuschko:gradle-docker-plugin:X.Y.Z'
}
}
为我工作。这是我找到它的链接:
https://www.codeproject.com/Questions/665556/Connection-Timeout-Problem-with-MySqlDataAdapter-h