我需要利用Maven / Jenkins版本中的Quicktest Pro。我知道,我知道QTP不是那里最好的工具(我被“火焰狗便便袋”reference逗乐了),但是我们的QE团队正在使用它,我想要运行他们的一些测试在詹金斯。
1A。有没有人用过这个特定的组合?一个示例/ maven插件会很棒。
由于我怀疑这是可能的,让我们将其分解成碎片。
2A。你如何从命令行简单地启动QTP测试?我想我可以使用antrun或类似的东西来计算其余的启动部分。
2B。 QTP的结果格式似乎并不像surefire报告那样标准(我不太清楚,所以我可能错了)。你能否给我一些关于将报告结果反馈给maven / Jenkins的指导?我想这可能涉及解析QTP结果文件。
答案 0 :(得分:6)
可以编写AOM(自动化对象模型)vbscript来调用QTP并运行特定测试。 这样的vbscript可以在Windows中从命令行运行。
如果你可以从Maven / Jenkins运行/调用vbscript文件,那么绝对可以通过命令行运行QTP脚本。
触发QTP运行的示例AOM vbscript函数位于
之下Public Function RunQTP(byVal strQC_Or_Local, byVal strTestPath, byVal strTestName, byVal strResultsFolder, byVal strTraceFile)', byVal strStore)
' Create the Application object
Dim objQTPApp,objQTPLibraries,objTestResults 'QTP
Dim strTempResultsRootFolder
strTempResultsRootFolder = "C:\TempTest\"
On Error Resume Next
'Loop for a minute or until qtp is successfully opened
StartTime = Now
Do
'Create QTP object
Set objQTPApp = CreateObject("QuickTest.Application")
'Clear any existing error numbers
Err.Clear
'If QTP is already launched, do nothing, else launch it
If objQTPApp.Launched = False Then
objQTPApp.Launch
End If
'Set qtp to visible
objQTPApp.Visible = True
'See if launching QTP has caused an error
intErr = Err.Number
'If it QTP has opened fine, exit the loop
If intErr = 0 Then
objQTPTraceFile.Write Now & " QTP open with no errors" & vbCR
Exit Do
'If there's an error, Close and QTP processes running (if any) and try again
Else
msgbox "Error in opening QTP"
End If
Loop Until DateDiff("s", StartTime, Now) > 180
On Error GoTo 0
objQTPApp.Options.Run.RunMode = "Fast"
If strQC_Or_Local = "QC" Then
'Connect To QC
strQCUsername = "Quality center username"
strQCPassword = "Quality center password"
If objQTPApp.TDConnection.IsConnected Then
'If QTP is already connected, if login details are different, then log out and log in again with given details
If objQTPApp.TDConnection.User <> strQCUsername Or objQTPApp.TDConnection.Domain <> strQCDomain Or _
objQTPApp.TDConnection.Project <> strQCProject Or objQTPApp.TDConnection.Server <> strQCPath Then
msgbox "connected as someone else - disconnecting, and then will reconnect"
objQTPApp.TDConnection.Disconnect
On Error Resume Next
objQTPApp.TDConnection.Connect strQCPath, strQCDomain, strQCProject, strQCUsername, strQCPassword, False
On Error GoTo 0
End If
Else
'If it's not already connected, log in with given details
On Error Resume Next
objQTPApp.TDConnection.Connect strQCPath, strQCDomain, strQCProject, strQCUsername, strQCPassword, False
On Error GoTo 0
End If
'If connected, tests in QC have [QualityCenter] appended before their name
If objQTPApp.TDConnection.IsConnected Then ' If connection is successful
strTestPath = "[QualityCenter] " & strTestPath
Else
MsgBox "Cannot connect to Quality Center" ' If connection is not successful, display an error message.
Exit Function
End If
End If
'Open the test
On Error Resume Next
objQTPApp.Open strTestPath, False
intErr = err.number
strErrDesc = err.description
On Error Goto 0
'If no problems
If intErr = 0 Then
'Configure the QTP settings
'Stop the test when an error occours
objQTPApp.Test.Settings.Run.OnError = "NextIteration"
'Select the Range you wish to run
objQTPApp.Test.Settings.Run.IterationMode = "oneIteration"
'Set sync timeout to be 20 seconds and disable smart identification
'objQTPApp.Test.Settings.Run.ObjectSyncTimeOut = 20000
objQTPApp.Test.Settings.Run.DisableSmartIdentification = True
'Ensure that the recovery mechanism is set to be activated for every step
'qtTestRecovery.SetActivationMode "OnError"
Set objTestResults = CreateObject("QuickTest.RunResultsOptions")
'If results folder path is empty, just save tests results to usual temp place
Dim blnSaveSpecificLocation
If strResultsFolder = "" Then
blnSaveSpecificLocation = False
objTestResults.ResultsLocation = "<TempLocation>"
Else
'Otherwise, save results to a temporary location, and then move the tests results to desired location before closing the test/stopping QTP etc
'Need to save to a temp location and then move, as it looks like that when another test is run, QTP deletes the previous set of results.
blnSaveSpecificLocation = True
'Create the results object
strDate = CStr(Now)
strDate = Replace(strDate, "/", "")
strDate = Replace(strDate, ":", ".")
strTestNameAppendage = strTestName & " " & objQTPApp.Test.Environment.Value("LocalHostName") & " " & strDate
strResults = strResultsFolder & "\" '& strTestNameAppendage
strTempResultsLocation = strTempResultsRootFolder & strTestNameAppendage
objTestResults.ResultsLocation = strTempResultsLocation
End If
objQTPTraceFile.Write Now & " Start Test" & vbCrLf
'If QTP crashes, it will be forced shut by 'KillQTP' after an hour. If this happens, 'objQTPApp.Test.Run objTestResults' will return an error
'so need to turn off error reporting and capture the error given if this is the case
On Error Resume Next
Dim intQTPErr
Err.Clear
'Run the test *************************** This is the line which triggers the QTP run
objQTPApp.Test.Run objTestResults
intQTPErr = Err.Number
On Error GoTo 0
objQTPTraceFile.Write Now & " End Test" & vbCrLf
Else
objQTPTraceFile.Write Now & " " & strTestPath & " could not be opened. Error message = " & strErrDesc & vbCRLf
End if
'Close Qtp
objQTPTraceFile.Write Now & " Just before checking the error number. Error Number was: " & intQTPErr & vbCRLf
On Error Resume Next
'If QTP has crashed, the number captured in intQTPErr will be -2147023170
If intQTPErr = "-2147023170" Then 'if it's crashed (could put <> 0 instead)
objQTPTraceFile.Write Now & " QTP Run Crashed or didn't finish in the time limit. Error Number was: " & intQTPErr & vbCRLf
Else
objQTPTraceFile.Write Now & " QTP Thinks it finished - stopping test: " & Err.Number & vbCRLf
'Close the test
objQTPApp.Test.Stop
objQTPTraceFile.Write Now & " QTP Thinks it stopped fine - closing test: " & Err.Number & vbCRLf
'Move the test from temp location to desired location
If blnSaveSpecificLocation = True Then
Call MoveFolder(strTempResultsLocation, strResults)
'objQTPApp.Test.Close
objQTPTraceFile.Write Now & " QTP Thinks it closed fine - error number is: " & Err.Number & vbCRLf
End If
objQTPTraceFile.Write Now & " QTP Process should have been killed" & vbCRLf
End If
On Error GoTo 0
'Set objects used to nothing
Set objQTPTraceFile = Nothing
Set fso = Nothing
Set qtTestRecovery = Nothing ' Release the Recovery object
Set objTestResults = Nothing
Set objQTPLibraries = Nothing
Set objQTPApp = Nothing
End Function