有没有办法立即停止在SQL Server中执行SQL脚本,比如“break”或“exit”命令?
我有一个脚本在开始插入之前执行一些验证和查找,如果任何验证或查找失败,我希望它停止。
答案 0 :(得分:339)
raiserror('Oh no a fatal error', 20, -1) with log
这将终止连接,从而阻止脚本的其余部分运行。
请注意,严重级别为20或更高级别以及WITH LOG
选项都必须以此方式工作。
这甚至适用于GO语句,例如
print 'hi'
go
raiserror('Oh no a fatal error', 20, -1) with log
go
print 'ho'
会给你输出:
hi
Msg 2745, Level 16, State 2, Line 1
Process ID 51 has raised user error 50000, severity 20. SQL Server is terminating this process.
Msg 50000, Level 20, State 1, Line 1
Oh no a fatal error
Msg 0, Level 20, State 0, Line 0
A severe error occurred on the current command. The results, if any, should be discarded.
请注意,'ho'未打印。
注意事项:
noexec方法
使用GO语句的另一种方法是set noexec on
。这会导致跳过脚本的其余部分。它不会终止连接,但您需要在执行任何命令之前再次关闭noexec
。
示例:
print 'hi'
go
print 'Fatal error, script will not continue!'
set noexec on
print 'ho'
go
-- last line of the script
set noexec off -- Turn execution back on; only needed in SSMS, so as to be able
-- to run this script again in the same session.
答案 1 :(得分:169)
只需使用RETURN(它将在存储过程的内部和外部工作)。
答案 2 :(得分:47)
如果你可以使用SQLCMD模式,那么咒语
:on error exit
(包括冒号)将导致RAISERROR实际停止脚本。如,
:on error exit
IF NOT EXISTS (SELECT * FROM sys.objects WHERE object_id = OBJECT_ID(N'[dbo].[SOMETABLE]') AND type in (N'U'))
RaisError ('This is not a Valid Instance Database', 15, 10)
GO
print 'Keep Working'
将输出:
Msg 50000, Level 15, State 10, Line 3
This is not a Valid Instance Database
** An error was encountered during execution of batch. Exiting.
并且批次将停止。如果未打开SQLCMD模式,您将获得有关冒号的解析错误。不幸的是,它并不是完全没有防御性的,就好像脚本是在没有处于SQLCMD模式的情况下运行一样,SQL Managment Studio正好经过了解析时间错误!不过,如果你从命令行运行它们,这很好。
答案 3 :(得分:21)
我不会使用RAISERROR- SQL具有可用于此目的的IF语句。进行验证和查找并设置局部变量,然后使用IF语句中的变量值使插入成为条件。
您不需要检查每个验证测试的变量结果。您通常只使用一个标志变量来确认所有条件通过:
declare @valid bit
set @valid = 1
if -- Condition(s)
begin
print 'Condition(s) failed.'
set @valid = 0
end
-- Additional validation with similar structure
-- Final check that validation passed
if @valid = 1
begin
print 'Validation succeeded.'
-- Do work
end
即使您的验证更复杂,您也只需要在最终检查中包含一些标志变量。
答案 4 :(得分:13)
我使用事务成功扩展了noexec开/关解决方案,以全有或全无的方式运行脚本。
set noexec off
begin transaction
go
<First batch, do something here>
go
if @@error != 0 set noexec on;
<Second batch, do something here>
go
if @@error != 0 set noexec on;
<... etc>
declare @finished bit;
set @finished = 1;
SET noexec off;
IF @finished = 1
BEGIN
PRINT 'Committing changes'
COMMIT TRANSACTION
END
ELSE
BEGIN
PRINT 'Errors occured. Rolling back changes'
ROLLBACK TRANSACTION
END
显然编译器“理解”IF中的@finished变量,即使出现错误并且执行被禁用。但是,仅当未禁用执行时,该值才设置为1。因此,我可以相应地提交或回滚事务。
答案 5 :(得分:12)
您可以将您的SQL语句包装在WHILE循环中,并在需要时使用BREAK
WHILE 1 = 1
BEGIN
-- Do work here
-- If you need to stop execution then use a BREAK
BREAK; --Make sure to have this break at the end to prevent infinite loop
END
答案 6 :(得分:12)
在SQL 2012+中,您可以使用THROW。
THROW 51000, 'Stopping execution because validation failed.', 0;
PRINT 'Still Executing'; -- This doesn't execute with THROW
来自MSDN:
引发异常并将执行转移到TRY ... CATCH构造的CATCH块...如果TRY ... CATCH构造不可用,则会话结束。设置引发异常的行号和过程。严重性设置为16。
答案 7 :(得分:8)
这是存储过程吗?如果是这样,我认为你可以做一个Return,例如“Return NULL”;
答案 8 :(得分:8)
进一步refinig Sglasses方法,上面的行强制使用SQLCMD模式,如果不使用SQLCMD模式则使用scirpt或者在出现任何错误时使用:on error exit
退出
CONTEXT_INFO用于跟踪状态。
SET CONTEXT_INFO 0x1 --Just to make sure everything's ok
GO
--treminate the script on any error. (Requires SQLCMD mode)
:on error exit
--If not in SQLCMD mode the above line will generate an error, so the next line won't hit
SET CONTEXT_INFO 0x2
GO
--make sure to use SQLCMD mode ( :on error needs that)
IF CONTEXT_INFO()<>0x2
BEGIN
SELECT CONTEXT_INFO()
SELECT 'This script must be run in SQLCMD mode! (To enable it go to (Management Studio) Query->SQLCMD mode)\nPlease abort the script!'
RAISERROR('This script must be run in SQLCMD mode! (To enable it go to (Management Studio) Query->SQLCMD mode)\nPlease abort the script!',16,1) WITH NOWAIT
WAITFOR DELAY '02:00'; --wait for the user to read the message, and terminate the script manually
END
GO
----------------------------------------------------------------------------------
----THE ACTUAL SCRIPT BEGINS HERE-------------
答案 9 :(得分:6)
我建议你在try catch块中包装适当的代码块。然后,您可以使用严重性为11的Raiserror事件,以便在需要时中断到catch块。如果你只是想要反复操作但是在try块中继续执行,那么使用较低的严重性。
有意义吗?
干杯, 约翰
[编辑包含BOL参考]
http://msdn.microsoft.com/en-us/library/ms175976(SQL.90).aspx
答案 10 :(得分:6)
您可以使用GOTO语句更改执行流程:
IF @ValidationResult = 0
BEGIN
PRINT 'Validation fault.'
GOTO EndScript
END
/* our code */
EndScript:
答案 11 :(得分:4)
这些都不适用于'GO'语句。在此代码中,无论严重性是10还是11,都会得到最终的PRINT语句。
测试脚本:
-- =================================
PRINT 'Start Test 1 - RAISERROR'
IF 1 = 1 BEGIN
RAISERROR('Error 1, level 11', 11, 1)
RETURN
END
IF 1 = 1 BEGIN
RAISERROR('Error 2, level 11', 11, 1)
RETURN
END
GO
PRINT 'Test 1 - After GO'
GO
-- =================================
PRINT 'Start Test 2 - Try/Catch'
BEGIN TRY
SELECT (1 / 0) AS CauseError
END TRY
BEGIN CATCH
SELECT ERROR_MESSAGE() AS ErrorMessage
RAISERROR('Error in TRY, level 11', 11, 1)
RETURN
END CATCH
GO
PRINT 'Test 2 - After GO'
GO
<强>结果:强>
Start Test 1 - RAISERROR
Msg 50000, Level 11, State 1, Line 5
Error 1, level 11
Test 1 - After GO
Start Test 2 - Try/Catch
CauseError
-----------
ErrorMessage
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Divide by zero error encountered.
Msg 50000, Level 11, State 1, Line 10
Error in TRY, level 11
Test 2 - After GO
使这项工作的唯一方法是编写没有GO
语句的脚本。有时这很容易。有时这很困难。 (使用类似IF @error <> 0 BEGIN ...
的内容。)
答案 12 :(得分:4)
您可以使用RAISERROR。
答案 13 :(得分:3)
这是我的解决方案:
...
BEGIN
raiserror('Invalid database', 15, 10)
rollback transaction
return
END
答案 14 :(得分:3)
您可以使用GOTO语句。试试这个。这是完全适合你。
var restService = {
'request': function(args) {
var deferred = $q.defer();
$http({
url: url,
withCredentials: this.use_session,
method: method.toUpperCase(),
headers: headers,
params: params,
data: data,
timeout: 20000
})
.success(angular.bind(this, function(data, status, headers, config) {
deferred.resolve(data, status);
}))
.error(angular.bind(this, function(data, status, headers, config) {
deferred.reject(data);
}
return deferred.promise;
}
'listAssignments': function(filters) {
return this.request({
'method': "GET",
'url': "/assignments/",
'params': filters
});
}
}; // end restService object
restService.listAssignments(filters)
.then(function(data) {
$log.debug("success " + data);
}, function(data) {
$log.debug("error " + data);
})
.finally(function() {
$log.debug("In finally.... calling scrollHelper");
});
答案 15 :(得分:2)
我一直在这里使用RETURN
,使用脚本或Stored Procedure
如果您在一个交易中,请确保ROLLBACK
交易,否则RETURN
会立即导致未提交的交易
答案 16 :(得分:1)
答案谢谢!
raiserror()
工作正常,但您不应忘记return
语句,否则脚本会继续运行而不会出错! (hense the raiserror不是“throwerror”;-))当然,如果有必要可以回滚!
raiserror()
很高兴告诉执行脚本的人出了什么问题。
答案 17 :(得分:1)
如果您只是在Management Studio中执行脚本,并希望在第一次错误时停止执行或回滚事务(如果使用),那么我认为最好的方法是使用try catch块(SQL 2005以后)。 如果您正在执行脚本文件,这在Management studio中运行良好。 存储过程也可以使用它。
答案 18 :(得分:1)
将其包含在try catch块中,然后将执行转移到catch。
BEGIN TRY
PRINT 'This will be printed'
RAISERROR ('Custom Exception', 16, 1);
PRINT 'This will not be printed'
END TRY
BEGIN CATCH
PRINT 'This will be printed 2nd'
END CATCH;
答案 19 :(得分:0)
回到过去,我们使用了以下方法……效果最好:
RAISERROR ('Error! Connection dead', 20, 127) WITH LOG
答案 20 :(得分:0)
非常感谢这里的所有其他人以及我阅读的其他帖子。 但在@jaraics 回答之前,没有什么能满足我的所有需求。
我见过的大多数答案都忽略了多批次的脚本。他们忽略了 SSMS 和 SQLCMD 中的双重用法。我的脚本完全可以在 SSMS 中运行——但我想要 F5 预防,这样他们就不会意外删除现有的一组对象。
SET PARSEONLY ON
可以很好地防止不需要的 F5。但是这样你就不能用 SQLCMD 运行了。
另一件让我慢了一段时间的事情是,当出现错误时,Batch 如何跳过任何进一步的命令 - 所以我的 SET NOCOUNT ON
被跳过,因此脚本仍然运行。
无论如何,我稍微修改了 jaraics 的回答:(在这种情况下,我还需要一个数据库才能从命令行处于活动状态)
-----------------------------------------------------------------------
-- Prevent accidental F5
-- Options:
-- 1) Highlight everything below here to run
-- 2) Disable this safety guard
-- 3) or use SQLCMD
-----------------------------------------------------------------------
set NOEXEC OFF -- Reset in case it got stuck ON
set CONTEXT_INFO 0x1 -- A 'variable' that can pass batch boundaries
GO -- important !
if $(SQLCMDDBNAME) is not null
set CONTEXT_INFO 0x2 -- If above line worked, we're in SQLCMD mode
GO -- important !
if CONTEXT_INFO()<>0x2
begin
select 'F5 Pressed accidentally.'
SET NOEXEC ON -- skip rest of script
END
GO -- important !
-----------------------------------------------------------------------
< rest of script . . . . . >
GO
SET NOEXEC OFF
print 'DONE'