我的气流Web服务器在格林尼治标准时间16:37的同一时间突然关闭。 我的气流调度程序运行正常(无崩溃)任务仍在运行。
除了没有太多错误之外。
pip3 install <yourModule>
这是引起记忆的原因吗? 我的Web服务器cfg设置是标准设置。
Handling signal: ttou
Worker exiting (pid: 118711)
ERROR - No response from gunicorn master within 120 seconds
ERROR - Shutting down webserver
Handling signal: term
Worker exiting
Worker exiting
Worker exiting
Worker exiting
Worker exiting
Shutting down: Master
更新: 好的,它不会每天崩溃,但是今天我有gillicorn无法重新启动日志。
# Number of seconds the webserver waits before killing gunicorn master that doesn't respond
web_server_master_timeout = 120
# Number of seconds the gunicorn webserver waits before timing out on a worker
web_server_worker_timeout = 120
# Number of workers to refresh at a time. When set to 0, worker refresh is
# disabled. When nonzero, airflow periodically refreshes webserver workers by
# bringing up new ones and killing old ones.
worker_refresh_batch_size = 1
# Number of seconds to wait before refreshing a batch of workers.
worker_refresh_interval = 30
更新:2020年10月30日
[严重]工作人员超时(pid:108237)
我明白了,我将超时时间增加到240,是默认值的两倍。