Bochs在磁盘启动选项上的INT 13h上不支持AH = 42h

时间:2019-06-26 03:10:04

标签: operating-system bootloader bios bochs

嗨,我正在用Bochs上的LBA寻址进行引导加载程序。

当执行AH = 42h的int 13h时,终端显示以下信息。

00017480939i[BIOS  ] int13_diskette: unsupported AH=42
00017481022i[XGUI  ] charmap update. Font is 9 x 16
Next at t=17481022

int 13h指令之前的寄存器如下:

<bochs:3> reg
CPU0:
rax: 00000000_00004200 rcx: 00000000_00090001
rdx: 00000000_00000000 rbx: 00000000_00008000
rsp: 00000000_00007be8 rbp: 00000000_00000000
rsi: 00000000_000e7be8 rdi: 00000000_00007fe0
r8 : 00000000_00000000 r9 : 00000000_00000000
r10: 00000000_00000000 r11: 00000000_00000000
r12: 00000000_00000000 r13: 00000000_00000000
r14: 00000000_00000000 r15: 00000000_00000000
rip: 00000000_00007d94
eflags 0x00000202: id vip vif ac vm rf nt IOPL=0 of df IF tf sf zf af pf cf
<bochs:4> sreg
es:0x0000, dh=0x00009300, dl=0x0000ffff, valid=1
        Data segment, base=0x00000000, limit=0x0000ffff, Read/Write, Accessed
cs:0x0000, dh=0x00009300, dl=0x0000ffff, valid=1
        Data segment, base=0x00000000, limit=0x0000ffff, Read/Write, Accessed
ss:0x0000, dh=0x00009300, dl=0x0000ffff, valid=7
        Data segment, base=0x00000000, limit=0x0000ffff, Read/Write, Accessed
ds:0x0000, dh=0x00009300, dl=0x0000ffff, valid=1
        Data segment, base=0x00000000, limit=0x0000ffff, Read/Write, Accessed
fs:0x0000, dh=0x00009300, dl=0x0000ffff, valid=1
        Data segment, base=0x00000000, limit=0x0000ffff, Read/Write, Accessed
gs:0x0000, dh=0x00009300, dl=0x0000ffff, valid=1
        Data segment, base=0x00000000, limit=0x0000ffff, Read/Write, Accessed
ldtr:0x0000, dh=0x00008200, dl=0x0000ffff, valid=1
tr:0x0000, dh=0x00008b00, dl=0x0000ffff, valid=1
gdtr:base=0x00000000000f9a37, limit=0x30
idtr:base=0x0000000000000000, limit=0x3ff

指向的16字节DS:SI是:

<bochs:6> xp /16b 0x7be8
[bochs]:
0x0000000000007be8 <bogus+       0>:    0x10    0x00    0x01    0x00    0x00    0x80    0x00    0x00
0x0000000000007bf0 <bogus+       8>:    0x19    0x00    0x00    0x00    0x00    0x00    0x00    0x00

AH的返回值为0x01,并且CF已设置。

我使用磁盘作为启动选项,并创建了一个磁盘映像文件,我的bochs配置的一部分如下:

boot: disk
floppy_bootsig_check: disabled=0
# no floppya
# no floppyb
ata0: enabled=1, ioaddr1=0x1f0, ioaddr2=0x3f0, irq=14
ata0-master: type=disk, path="Boot.img", mode=flat, cylinders=0, heads=0, spt=0, model="Generic 1234", biosdetect=auto, translation=auto
ata0-slave: type=none

我的平台是Ubuntu 18.4,Bochs 2.6.9,以下是我的配置选项:

./configure --enable-plugins --enable-debugger --enable-disasm --enable-readline --enable-cpu-level=6 --enable-smp --enable-x86-64 --enable-avx --enable-a20-pin --enable-fast-function-calls --enable-all-optimizations --enable-x86-debugger --enable-alignment-check --enable-sb16

现在我的问题是如何为BIOS启用AH = 42h选项。

谢谢!

1 个答案:

答案 0 :(得分:3)

大多数真实的计算机和Bochs对于大多数/更大的设备(硬盘,CD / DVD等)都支持“ int 0x13扩展名”,但对于软盘不支持。

  

int 13h指令之前的寄存器如下:

     

rdx:00000000_00000000

这意味着“ {DL =驱动器号= 0x00 =第一张软盘”。

  

现在我的问题是如何为BIOS启用AH = 42h选项。

如果您打算使用“ int 0x13扩展名”访问第一个软盘;然后不这样做(您想编写自己的“ LBA-> CHS”例程,该例程考虑“引导后插入”软盘的几何形状)。

如果您打算访问从中引导的硬盘驱动器,那么在引导加载程序启动的很早之前,您要将值存储在已传递的DL(“引导加载程序来自的设备号”)中到引导加载程序,以便您可以将其重新加载到DL中,以便以后进行磁盘读/写操作。请注意,该值可能不是0x80(例如,任何类型的引导管理器决定在第二个硬盘驱动器上引导OS),并且(对于分区硬盘)引导加载程序还希望存储有关它来自的分区的信息(因此它可以执行“ LBA =我的分区中的阻止+我分区的第一个扇区的LBA”并进行限制检查)。