我正在构建一个HTA / Batch脚本,该脚本包含一个界面,供用户向该脚本发送htareply,该界面将向服务器发送链接以在Jenkins上执行构建脚本。一切正常,但是我想知道是否可以将hta窗口保持打开状态,以便用户根据需要选择其他选项。有什么想法吗?
我尝试从javascript中删除window.close()
,但随后它没有将htareply发送到批处理脚本。
<!-- :: Batch section
@echo off
setlocal
echo Select an option:
for /F "delims=" %%a in ('mshta.exe "%~F0"') do set "HTAreply=%%a"
echo End of HTA window, reply: "%HTAreply%"
PAUSE
goto :EOF
-->
<HTML>
<HEAD>
<HTA:APPLICATION SCROLL="no" SYSMENU="no" >
<TITLE>HTA Radio Buttons</TITLE>
<SCRIPT language="JavaScript">
window.resizeTo(440,170);
var reply = "No button selected";
function sendreply(){
var fso = new ActiveXObject("Scripting.FileSystemObject");
fso.GetStandardStream(1).WriteLine(reply);
//window.close();
}
</SCRIPT>
</HEAD>
<BODY>
<p>Select an option.</p>
<label><input type="radio" name="option1" onclick="reply=this.value"
value="option1">Option1</label>
<label><input type="radio" name="option2" onclick="reply=this.value"
value="option2">Option2</label>
<label><input type="radio" name="option3" onclick="reply=this.value"
value="option3">Option3</label>
<br><br>
<button onclick="sendreply()">Submit</button>
<button onclick="window.close()">Close</button>
</BODY>
</HTML>
我想发生的是,如果用户选择并选择并提交,则hta窗口将保持打开状态,直到他们选择“关闭”为止。
答案 0 :(得分:2)
for /F
命令的工作方式如下: first 执行嵌套命令,收集其所有输出并等待其终止; 然后开始使用收集到的行在for
正文中执行命令。因此,如果要同时(并行)执行,可以不使用for /F
。
您可以使用左侧的HTA部分和右侧的Batch部分的管道。但是,当set /P
命令从管道读取输入时,它表现出奇怪的行为...
解决方案是使用辅助文件,因此将HTA部分写入其中,并从中读取Batch部分:
<!-- :: Batch section
@echo off
setlocal
rem Initialize Batch side interface the first time
if "%~1" equ "interface" goto :interface
rem Empty pipe file
cd . > pipeFile.txt
echo Select an option:
rem Start HTA-Batch interface
mshta.exe "%~F0" >> pipeFile.txt | "%~F0" interface < pipeFile.txt
PAUSE
del pipeFile.txt
goto :EOF
:interface
set "HTAreply="
set /P "HTAreply="
if "%HTAreply%" equ "" goto interface
echo Reply: "%HTAreply%"
if "%HTAreply%" neq "EOF" goto interface
echo End of HTA window
goto :EOF
-->
<HTML>
<HEAD>
<HTA:APPLICATION SCROLL="no" SYSMENU="no" >
<TITLE>HTA Radio Buttons</TITLE>
<SCRIPT language="JavaScript">
window.resizeTo(440,170);
var reply = "No button selected";
var fso = new ActiveXObject("Scripting.FileSystemObject");
function sendreply(){
fso.GetStandardStream(1).WriteLine(reply);
//window.close();
}
</SCRIPT>
</HEAD>
<BODY>
<p>Select an option.</p>
<label><input type="radio" name="option1" onclick="reply=this.value"
value="option1">Option1</label>
<label><input type="radio" name="option2" onclick="reply=this.value"
value="option2">Option2</label>
<label><input type="radio" name="option3" onclick="reply=this.value"
value="option3">Option3</label>
<br><br>
<button onclick="sendreply()">Submit</button>
<button onclick="fso.GetStandardStream(1).WriteLine('EOF'); window.close()">Close</button>
</BODY>
</HTML>
在此解决方案中,HTA和批处理零件是通过管道|
启动的,只是要同时运行;请记住,这两个部分之间的通信是通过pipeFile执行的。