我有这样的线路协议:
Measurement1,Valuetype=Act_value,metric=Max,dt=Int value=200i 1553537228984000000
Measurement1,Valuetype=Act_value,metric=Lower_bound,dt=Int value=25i 1553537228987000000
Measurement1,Valuetype=Act_value,metric=Min,dt=Int value=10i 1553537228994000000
Measurement1,Valuetype=Act_value,metric=Upper_limit,dt=Int value=222i 1553537228997000000
Measurement1,Valuetype=Act_value,metric=Lower_limit,dt=Int value=0i 1553537229004000000
Measurement1,Valuetype=Act_value,metric=Simulation,dt=bool value=False 1553537229007000000
Measurement1,Valuetype=Act_value,metric=Value,dt=Int value=69i 1553537229014000000
Measurement1,Valuetype=Act_value,metric=Percentage,dt=Int value=31i 1553537229017000000
Measurement1,Valuetype=Set_value,metric=Upper_limit,dt=Int value=222i 1553537229024000000
Measurement1,Valuetype=Set_value,metric=Lower_limit,dt=Int value=0i 1553537229028000000
Measurement1,Valuetype=Set_value,metric=Unit,dt=string value="Kelvin" 1553537229035000000
Measurement1,Valuetype=Set_value,metric=Value,dt=Int value=222i 1553537229038000000
Measurement1,Valuetype=Set_value,metric=Percentage,dt=Int value=0i 1553537229045000000
我需要一次插入多行。问题可能是我将整数,布尔值和字符串插入同一张表中。当我创建测量值(例如Measurement1_Int
,Measurement1_bool
,Measurement1_string
。在上述配置中,我得到一个错误。
我有以下问题:
答案 0 :(得分:1)
如果您有能力为测量数据点内的所有指标分配相同的时间戳,则最好的选择是在influxdb记录中使用指标名称和字段名称:
Measurement1,Valuetype=Act_value Max=200i,Lower_bound=25i,Min=10i,Upper_limit=222i,Lower_limit=0i,Simulation=False,Value=69i,Percentage=31i 1553537228984000000
否则,您仍然可以使用度量标准名称作为字段名称,但是每个时间戳的缺失字段将具有空值:
Measurement1,Valuetype=Set_value Upper_limit=222i 1553537229024000000
Measurement1,Valuetype=Set_value Lower_limit=0i 1553537229028000000
Measurement1,Valuetype=Set_value Unit="Kelvin" 1553537229035000000
Measurement1,Valuetype=Set_value Value=222i 1553537229038000000
Measurement1,Valuetype=Set_value Percentage=0i 1553537229045000000