如何解决Inedo Hub Proget安装错误?

时间:2018-11-02 09:35:50

标签: proget

我正在尝试在我的2012服务器上安装proget, 我收到这些错误,这可能是由于配置错误 请让我知道集成网址和Feed网址。

enter image description here enter image description here

产品:ProGet 版本:5.1.15

System.Data.SqlClient.SqlException(0x80131904):无效的对象名称“配置”。    在System.Data.SqlClient.SqlConnection.OnError(SqlException异常,布尔breakConnection,Action 1 wrapCloseInAction) at System.Data.SqlClient.TdsParser.ThrowExceptionAndWarning(TdsParserStateObject stateObj, Boolean callerHasConnectionLock, Boolean asyncClose) at System.Data.SqlClient.TdsParser.TryRun(RunBehavior runBehavior, SqlCommand cmdHandler, SqlDataReader dataStream, BulkCopySimpleResultSet bulkCopyHandler, TdsParserStateObject stateObj, Boolean& dataReady) at System.Data.SqlClient.SqlDataReader.TryConsumeMetaData() at System.Data.SqlClient.SqlDataReader.get_MetaData() at System.Data.SqlClient.SqlCommand.FinishExecuteReader(SqlDataReader ds, RunBehavior runBehavior, String resetOptionsString, Boolean isInternal, Boolean forDescribeParameterEncryption, Boolean shouldCacheForAlwaysEncrypted) at System.Data.SqlClient.SqlCommand.RunExecuteReaderTds(CommandBehavior cmdBehavior, RunBehavior runBehavior, Boolean returnStream, Boolean async, Int32 timeout, Task& task, Boolean asyncWrite, Boolean inRetry, SqlDataReader ds, Boolean describeParameterEncryptionRequest) at System.Data.SqlClient.SqlCommand.RunExecuteReader(CommandBehavior cmdBehavior, RunBehavior runBehavior, Boolean returnStream, String method, TaskCompletionSource 1完成,Int32超时,任务和任务,布尔和usedCache,布尔asyncWrite,布尔inRetry)中    在System.Data.SqlClient.SqlCommand.RunExecuteReader(CommandBehavior cmdBehavior,RunBehavior runBehavior,Boolean returnStream,String方法)    在System.Data.SqlClient.SqlCommand.ExecuteScalar()    在Inedo.Hub.Data.InstalledProduct.g__readDbConfigValue | 59_0(字符串键,<> c__DisplayClass59_0&)在C:\ InedoAgent \ BuildMasterTemp \ Temp_E80991 \ Src \ src \ InedoHubCore \ Data \ InstalledProduct.cs:line 161    位于C:\ InedoAgent \ BuildMasterTemp \ Temp_E80991 \ Src \ src \ InedoHubCore \ Data \ InstalledProduct.cs:line 151中的Inedo.Hub.Data.InstalledProduct.ScrapeFromInstallation(String targetPath) ClientConnectionId:674594c1-dcf5-4bac-9fec-44a7a4756ba3 错误号:208,状态:1,类别:16

1 个答案:

答案 0 :(得分:0)

Inedo集线器[config]中的集成URL应该为https://my.inedo.com/services/v1

要更改ProGet侦听的端口,请在安装后使用“配置”选项卡。

如果以前未在此计算机上成功安装ProGet,则删除%ProgramData%\Inedo\SharedConfig\ProGet.config上的文件将阻止Inedo Hub尝试从数据库读取数据。