WinAppDriver WindowsDriver <windowselement>网址问题

时间:2018-10-24 16:17:46

标签: winappdriver

我有一个解决方案,它实际上是一个有关Win App Driver如何工作的演示,但我终生无法使其正常工作。将Win App Driver与selenium和appium Web驱动程序配合使用(如this video第5分钟提到的那样)。我有如下所示的解决方案,当我运行AddAlarm测试时收到错误消息……“目标计算机主动拒绝了它127.0.0.1:4723”。

完整的错误消息在这篇文章的底部。

我的问题是,要使我们正在测试的应用程序“闹钟”实际上在URL 127.0.0.1:4723上启动,我需要做些什么才能使其在该URL上可用/ 港口?另外,如何验证设置中的“ app”和“ Microsoft.WindowsAlarms_8wekyb3d8bbwe!App”是否正确?

//Class with my test "AddAlarm"
using Microsoft.VisualStudio.TestTools.UnitTesting;
using OpenQA.Selenium.Appium.Windows;
using System.Threading;
using System;

namespace AlarmClockTest
{
    [TestClass]
    public class ScenarioAlarm : AutoTest_SynTQ.UnitTestSession
    {
        private const string NewAlarmName = "Sample Test Alarm";

        [TestMethod]
        public void AlarmAdd()
        {
            // Navigate to New Alarm page
            session.FindElementByAccessibilityId("AddAlarmButton").Click();

            // Set alarm name
            session.FindElementByAccessibilityId("AlarmNameTextBox").Clear();
            session.FindElementByAccessibilityId("AlarmNameTextBox").SendKeys(NewAlarmName);

            // Set alarm hour
            WindowsElement hourSelector = session.FindElementByAccessibilityId("HourLoopingSelector");
            hourSelector.FindElementByName("3").Click();
            Assert.AreEqual("3", hourSelector.Text);

            // Set alarm minute
            WindowsElement minuteSelector = session.FindElementByAccessibilityId("MinuteLoopingSelector");
            minuteSelector.FindElementByName("55").Click();
            Assert.AreEqual("55", minuteSelector.Text);

            // Save the newly configured alarm
            session.FindElementByAccessibilityId("AlarmSaveButton").Click();
            Thread.Sleep(TimeSpan.FromSeconds(3));

            // Verify that a new alarm entry is created with the given hour, minute, and name
            WindowsElement alarmEntry = session.FindElementByXPath($"//ListItem[starts-with(@Name, \"{NewAlarmName}\")]");
            Assert.IsNotNull(alarmEntry);
            Assert.IsTrue(alarmEntry.Text.Contains("3"));
            Assert.IsTrue(alarmEntry.Text.Contains("55"));
            Assert.IsTrue(alarmEntry.Text.Contains(NewAlarmName));

            // Verify that the alarm is active and deactivate it
            WindowsElement alarmEntryToggleSwitch = alarmEntry.FindElementByAccessibilityId("AlarmToggleSwitch") as WindowsElement;
            Assert.IsTrue(alarmEntryToggleSwitch.Selected);
            alarmEntryToggleSwitch.Click();
            Assert.IsFalse(alarmEntryToggleSwitch.Selected);
        }


        [ClassInitialize]
        public static void ClassInitialize(TestContext context)
        {
            Setup(context);
        }

        [ClassCleanup]
        public static void ClassCleanup()
        {
            // Try to delete any alarm entry that may have been created
            while (true)
            {
                try
                {
                    var alarmEntry = session.FindElementByXPath($"//ListItem[starts-with(@Name, \"{NewAlarmName}\")]");
                    session.Mouse.ContextClick(alarmEntry.Coordinates);
                    session.FindElementByName("Delete").Click();
                }
                catch
                {
                    break;
                }
            }

            TearDown();
        }

        [TestInitialize]
        public override void TestInit()
        {
            // Invoke base class test initialization to ensure that the app is in the main page
            base.TestInit();

            // Navigate to Alarm tab
            session.FindElementByAccessibilityId("AlarmPivotItem").Click();
        }
    }
}




//Inherited class below
using Microsoft.VisualStudio.TestTools.UnitTesting;
using OpenQA.Selenium.Appium.Windows;
using OpenQA.Selenium.Remote;
using System;
using System.Threading;

namespace AutoTest_SynTQ
{
    [TestClass]
    public class UnitTestSession
    {
        private const string WindowsApplicationDriverUrl = "http://127.0.0.1:4723";
        private const string AlarmClockAppId = "Microsoft.WindowsAlarms_8wekyb3d8bbwe!App";

        protected static WindowsDriver<WindowsElement> session;
        protected static RemoteTouchScreen touchScreen;

        public static void Setup(TestContext context)
        {
            // Launch Alarms & Clock application if it is not yet launched
            if (session == null || touchScreen == null)
            {
                TearDown();

                // Create a new session to bring up the Alarms & Clock application
                DesiredCapabilities appCapabilities = new DesiredCapabilities();
                appCapabilities.SetCapability("app", AlarmClockAppId);
                session = new WindowsDriver<WindowsElement>(new Uri(WindowsApplicationDriverUrl), appCapabilities);
                Assert.IsNotNull(session);
                Assert.IsNotNull(session.SessionId);

                // Set implicit timeout to 1.5 seconds to make element search to retry every 500 ms for at most three times
                session.Manage().Timeouts().ImplicitlyWait(TimeSpan.FromSeconds(1.5));

                // Initialize touch screen object
                touchScreen = new RemoteTouchScreen(session);
                Assert.IsNotNull(touchScreen);
            }
        }

        public static void TearDown()
        {
            // Cleanup RemoteTouchScreen object if initialized
            touchScreen = null;

            // Close the application and delete the session
            if (session != null)
            {
                session.Quit();
                session = null;
            }
        }

        [TestInitialize]
        public virtual void TestInit()
        {
            WindowsElement alarmTabElement = null;

            // Attempt to go back to the main page in case Alarms & Clock app is started in EditAlarm view
            try
            {
                alarmTabElement = session.FindElementByAccessibilityId("AlarmPivotItem");
            }
            catch
            {
                // Click back button if application is in a nested page such as New Alarm or New Timer
                session.FindElementByAccessibilityId("Back").Click();
                Thread.Sleep(TimeSpan.FromSeconds(1));
                alarmTabElement = session.FindElementByAccessibilityId("AlarmPivotItem");
            }

            // Verify that the app is in the main view showing alarmTabElement
            Assert.IsNotNull(alarmTabElement);
            Assert.IsTrue(alarmTabElement.Displayed);
        }
    }
}

测试名称:AlarmAdd 测试全名:AlarmClockTest.ScenarioAlarm.AlarmAdd 测试源:C:\ Users \ ECombe.OPTIDOORS \ Documents \ SynTQCodedUITesting \ AutoTest_SynTQ \ SCN_Alarm.cs:第30行 测试结果:失败 测试时间:0:00:00

结果StackTrace:
在OpenQA.Selenium.Remote.RemoteWebDriver.UnpackAndThrowOnError(Response errorResponse)    在OpenQA.Selenium.Remote.RemoteWebDriver.Execute处(字符串driverCommandToExecute,字典2 parameters) at OpenQA.Selenium.Remote.RemoteWebDriver.StartSession(ICapabilities desiredCapabilities) at OpenQA.Selenium.Remote.RemoteWebDriver..ctor(ICommandExecutor commandExecutor, ICapabilities desiredCapabilities) at OpenQA.Selenium.Appium.AppiumDriver 1..ctor(Uri remoteAddress,ICapabilitiesdesirableCapabilities)    在OpenQA.Selenium.Appium.Windows.WindowsDriver 1..ctor(Uri remoteAddress, DesiredCapabilities desiredCapabilities) at AutoTest_SynTQ.UnitTestSession.Setup(TestContext context) in C:\Users\ECombe.OPTIDOORS\Documents\SynTQCodedUITesting\AutoTest_SynTQ\UnitTestSession.cs:line 28 at AlarmClockTest.ScenarioAlarm.ClassInitialize(TestContext context) in C:\Users\ECombe.OPTIDOORS\Documents\SynTQCodedUITesting\AutoTest_SynTQ\SCN_Alarm.cs:line 71 Result Message: Class Initialization method AlarmClockTest.ScenarioAlarm.ClassInitialize threw exception. OpenQA.Selenium.WebDriverException: OpenQA.Selenium.WebDriverException: Unexpected error. System.Net.WebException: Unable to connect to the remote server ---> System.Net.Sockets.SocketException: No connection could be made because the target machine actively refused it 127.0.0.1:4723 at System.Net.Sockets.Socket.DoConnect(EndPoint endPointSnapshot, SocketAddress socketAddress) at System.Net.ServicePoint.ConnectSocketInternal(Boolean connectFailure, Socket s4, Socket s6, Socket& socket, IPAddress& address, ConnectSocketState state, IAsyncResult asyncResult, Exception& exception) --- End of inner exception stack trace --- at OpenQA.Selenium.Appium.Service.AppiumCommandExecutor.Execute(Command commandToExecute) at OpenQA.Selenium.Remote.RemoteWebDriver.Execute(String driverCommandToExecute, Dictionary 2个参数中)。

1 个答案:

答案 0 :(得分:0)

在我看来,答案是使用开发人员模式。实际的问题是winappdriver.exe立即关闭。更多详细信息here