当我为Kontakt信标选择Eddystone协议时,我走错了距离。
对于Kontakt,RSSI具有不同的值:
Tx Power RSSI for ibeacon @ 1m RSSI for Eddystone @ 0m
0 (-30dBm) -115 -74
1 (-20dBm) -84 -43
2 (-16dBm) -81 -40
3 (-12dBm) -77 -36
4 (-8dBm) -72 -31
5 (-4dBm) -69 -28
6 (0dBm) -65 -24
7 (4dBm) -59 -18
为什么使用Eddystone时所有距离都这么远,而当我使用iBeacon时一切正常?
这是我的代码的示例:
public static let signalLossAtOneMeter: Int = -41
public static func calculateDistance(rssi: Float, calibratedRssi: Float, calibratedDistance: Float, pathLossParameter: Float) -> Float {
return calculateDistance(rssi: rssi,
calibratedRssi: getCalibratedRssiAtOneMeter(calibratedRssi: calibratedRssi, calibratedDistance: calibratedDistance),
pathLossParameter: BeaconDistanceCalculator.pathLossParameter)
}
public static func getCalibratedRssiAtOneMeter(calibratedRssi: Float, calibratedDistance: Float) -> Float {
let calibratedRssiAtOneMeter: Float
if calibratedDistance == IBeacon.calibrationDistanceDefault {
calibratedRssiAtOneMeter = calibratedRssi
} else if calibratedDistance == Eddystone.calibrationDistanceDefault {
calibratedRssiAtOneMeter = calibratedRssi + Float(BeaconDistanceCalculator.signalLossAtOneMeter)
} else {
calibratedRssiAtOneMeter = -62
}
return calibratedRssiAtOneMeter
}
public static func calculateDistance(rssi: Float, calibratedRssi: Float, pathLossParameter: Float) -> Float {
return pow(10, (calibratedRssi - rssi) / (10 * pathLossParameter)) as Float
}
答案 0 :(得分:0)
我不确定getCalibratedRssiAtOneMeter
方法中的逻辑打算完成什么-根据每个信标的发射器在其安装位置的强度,这应该是一个固定值。实际上,您应该测量此值而不是使用制造商的查找表,因为它可能由于反射而变化(一些附近的物体充当“背板”并增强信号),而另一些衰减它。
Eddystone的关键在于,它将信标数据包中经过校准的RSSI编码为0m参考值,而不是iBeacon的1m参考值。这实际上意味着在从Eddystone数据包中读取常数之后,必须在常数之前添加-41才能将其插入公式中。这会将0m参考值转换为1m参考值。
如果不进行此转换,则距离估算值在Eddystone上会显得太远。