使用Indy的TIdTCPServer
组件,可以分两部分接收一个程序包,但是客户端发送了一个64 KB的程序包。
如何在服务器OnExecute
事件中收到完整的软件包?
现在,我放置了一个原型(服务器和客户端)代码来重新创建这种情况。
服务器代码
procedure TFrmServer.IdTCPServer1Execute(AContext: TIdContext);
Var
ReceivedBytesTCP : Integer;
IBuf : TIdBytes;
begin
if Not AContext.Connection.IOHandler.InputBufferIsEmpty then Begin
Try
ReceivedBytesTCP := AContext.Connection.IOHandler.InputBuffer.Size;
SetLength(IBuf,ReceivedBytesTCP);
AContext.Connection.IOHandler.ReadBytes(IBuf,ReceivedBytesTCP,False);
AContext.Connection.IOHandler.Write(IBuf,Length(IBuf),0);
Except
On E : Exception Do Begin
Memo1.Lines.Add('Except Server TCP: ' + E.Message);
End;
End;
End Else Begin
Sleep(1);
End;
end;
客户代码
procedure TFrm_TCP_Client.BtnSendClick(Sender: TObject);
Var
IBuf,RBuf : TIdBytes;
I : Integer;
LenPacket : Integer;
begin
LenPacket := StrToInt(EdtLength.Text);
if IdTCPClient1.Connected then Begin
SetLength(IBuf,LenPacket);
for I := 1 to LenPacket do
IBuf[I] := 1;
IdTCPClient1.IOHandler.Write(IBuf,Length(IBuf),0);
I := 0;
Repeat
IdTCPClient1.IOHandler.CheckForDataOnSource(50);
Inc(I);
Until Not IdTCPClient1.IOHandler.InputBufferIsEmpty or (I >= 10);
If Not IdTCPClient1.IOHandler.InputBufferIsEmpty Then Begin
SetLength(RBuf,IdTCPClient1.IOHandler.InputBuffer.Size);
IdTCPClient1.IOHandler.ReadBytes(RBuf,IdTCPClient1.IOHandler.InputBuffer.Size,False);
if Length(RBuf) = Length(IBuf) then
Memo1.Lines.Add('Response Received OK: '+IntToStr(Length(RBuf)))
Else
Memo1.Lines.Add('Response Received With Different Length: '+IntToStr(Length(RBuf)));
if Not IdTCPClient1.IOHandler.InputBufferIsEmpty then
Memo1.Lines.Add('Llego otro Mensaje');
End Else Begin
Memo1.Lines.Add('NO Response Received');
End;
End;
end;
如何知道消息是第一个还是第二个片段? 如何强制接收第二个片段?
答案 0 :(得分:5)
TCP中的发送和读取之间没有一对一的关系。可以自由分割数据,但是它希望优化网络传输。 TCP仅保证数据已发送,并且发送顺序相同,但是在传输过程中,HOW数据不会有任何碎片。 TCP将在接收端重建片段。这只是TCP的工作方式,并非Indy独有。无论使用哪种TCP框架,每个TCP应用程序都必须处理此问题。
如果您期望64KB的数据,那么只需读取64KB的数据,然后让OS和Indy内部为您处理这些碎片。 TCP的这种碎片正是为什么Indy的IOHandler
在将数据拼接在一起时使用InputBuffer
收集碎片的原因。
更新:停止关注片段。这是您不在其上操作的TCP层的实现细节。您无需处理代码中的片段。让Indy为您处理。只需关注您的应用程序级别协议即可。
仅供参考,您实际上已经实现了ECHO客户端/服务器解决方案。 Indy具有实际的ECHO客户/服务器组件TIdECHO
和TIdECHOServer
,您应该看看它们。
无论如何,您的服务器端异常处理都非常有问题。它未与主UI线程同步(在工作线程中调用OnExecute
)。但是,更重要的是,这就像在客户端连接丢失/断开时阻止TIdTCPServer
处理Indy本身发出的任何通知一样,因此客户端线程将保持运行状态,直到您停用服务器后才会停止。请勿吞下Indy自身的异常(这些异常源自EIdException
)。如果需要在代码中捕获它们,则应在完成后重新引发它们,让TIdTCPServer
处理它们。但是,在您的示例中,完全删除try..except
并使用服务器的OnException
事件会更容易。
此外,您的客户端阅读循环对于您尝试使用的循环是错误的。您没有正确初始化IBuf
。但是,更重要的是,您使用的超时时间非常短(TCP连接可能会有延迟),并且一旦任何数据到达或经过了500ms(即使有更多数据仍在继续。您应该一直在阅读,直到没有东西可供阅读为止。
请尝试以下类似操作:
服务器:
procedure TFrmServer.IdTCPServer1Execute(AContext: TIdContext);
var
IBuf : TIdBytes;
begin
AContext.Connection.IOHandler.ReadBytes(IBuf, -1);
AContext.Connection.IOHandler.Write(IBuf);
end;
procedure TFrmServer.IdTCPServer1Exception(AContext: TIdContext, AException: Exception);
var
Msg: string;
begin
if AException <> nil then
Msg := AException.Message
else
Msg := 'Unknown';
TThread.Queue(nil,
procedure
begin
Memo1.Lines.Add('Except Server TCP: ' + Msg);
end
);
end;
客户:
procedure TFrm_TCP_Client.BtnSendClick(Sender: TObject);
Var
IBuf,RBuf : TIdBytes;
LenPacket : Integer;
begin
if not IdTCPClient1.Connected then Exit;
LenPacket := StrToInt(EdtLength.Text);
if LenPacket < 1 then Exit;
SetLength(IBuf, LenPacket);
FillBytes(IBuf, LenPacket, $1);
try
IdTCPClient1.IOHandler.InputBuffer.Clear;
IdTCPClient1.IOHandler.Write(IBuf);
except
Memo1.Lines.Add('Request Send Error');
Exit;
end;
try
while IdTCPClient1.IOHandler.CheckForDataOnSource(500) do;
if not IdTCPClient1.IOHandler.InputBufferIsEmpty then
begin
IdTCPClient1.IOHandler.ReadBytes(RBuf, IdTCPClient1.IOHandler.InputBuffer.Size, True);
if Length(RBuf) = Length(IBuf) then
Memo1.Lines.Add('Response Received OK: ' + IntToStr(Length(RBuf)))
else
Memo1.Lines.Add('Response Received With Different Length. Expected: ' + IntToStr(Length(IBuf)) + ', Got: ' + IntToStr(Length(RBuf)));
end
else
Memo1.Lines.Add('NO Response Received');
except
Memo1.Lines.Add('Response Receive Error');
end;
end;
更好的解决方案是完全不依赖此类逻辑,更明确地说明数据协议的结构,例如<length><data>
,例如:
服务器:
procedure TFrmServer.IdTCPServer1Execute(AContext: TIdContext);
var
IBuf : TIdBytes;
LenPacket : Int32;
begin
LenPacket := AContext.Connection.IOHandler.ReadInt32;
AContext.Connection.IOHandler.ReadBytes(IBuf, LenPacket, True);
AContext.Connection.IOHandler.Write(LenPacket);
AContext.Connection.IOHandler.Write(IBuf);
end;
procedure TFrmServer.IdTCPServer1Exception(AContext: TIdContext, AException: Exception);
var
Msg: string;
begin
if AException <> nil then
Msg := AException.Message
else
Msg := 'Unknown';
TThread.Queue(nil,
procedure
begin
Memo1.Lines.Add('Except Server TCP: ' + Msg);
end
);
end;
客户:
procedure TFrm_TCP_Client.BtnSendClick(Sender: TObject);
Var
IBuf,RBuf : TIdBytes;
LenPacket : Int32;
begin
if not IdTCPClient1.Connected then Exit;
LenPacket := StrToInt(EdtLength.Text);
if LenPacket < 1 then Exit;
SetLength(IBuf, LenPacket);
FillBytes(IBuf, LenPacket, $1);
try
IdTCPClient1.IOHandler.InputBuffer.Clear;
IdTCPClient1.IOHandler.Write(LenPacket);
IdTCPClient1.IOHandler.Write(IBuf);
except
Memo1.Lines.Add('Request Send Error');
Exit;
end;
try
IdTCPClient1.IOHandler.ReadTimeout := 5000;
LenPacket := IdTCPClient1.IOHandler.ReadInt32;
IdTCPClient1.IOHandler.ReadBytes(RBuf, LenPacket, True);
except
Memo1.Lines.Add('Response Receive Error');
Exit;
end;
Memo1.Lines.Add('Response Received OK');
end;