我使用yocto为Jetson TX2模块构建了一个图像。一切都很好几天,但现在当我尝试刷新设备时,我得到了这个错误。
Welcome to Tegra Flash
version 1.0.0
Type ? or help for help and q or quit to exit
Use ! to execute system commands
[ 0.0008 ] tegrasign_v2 --key None --getmode mode.txt
[ 0.0016 ] Assuming zero filled SBK key
[ 0.0016 ]
[ 0.0016 ] Generating RCM messages
[ 0.0023 ] tegrarcm_v2 --listrcm rcm_list.xml --chip 0x18 --download rcm mb1_recovery_prod.bin 0 0
[ 0.0030 ] RCM 0 is saved as rcm_0.rcm
[ 0.0033 ] RCM 1 is saved as rcm_1.rcm
[ 0.0033 ] List of rcm files are saved in rcm_list.xml
[ 0.0033 ]
[ 0.0033 ] Signing RCM messages
[ 0.0040 ] tegrasign_v2 --key None --list rcm_list.xml --pubkeyhash pub_key.key
[ 0.0046 ] Assuming zero filled SBK key
[ 0.0076 ]
[ 0.0076 ] Copying signature to RCM mesages
[ 0.0083 ] tegrarcm_v2 --chip 0x18 --updatesig rcm_list_signed.xml
[ 0.0093 ]
[ 0.0093 ] Parsing partition layout
[ 0.0100 ] tegraparser_v2 --pt flash.xml.tmp
[ 0.0109 ]
[ 0.0109 ] Creating list of images to be signed
[ 0.0116 ] tegrahost_v2 --chip 0x18 --partitionlayout flash.xml.bin --list images_list.xml zerosbk
[ 0.0124 ] Stat for tegra186-quill-p3310-1000-c03-00-base.dtb failed
[ 0.0161 ]
Error: Return value 4
Command tegrahost_v2 --chip 0x18 --partitionlayout flash.xml.bin --list images_list.xml zerosbk
此错误是否会响铃?
我可以使用JetPack刷新电路板。
谢谢,
-Damien
答案 0 :(得分:0)
以防万一您从未想过,看起来像
[ 0.0124 ] Stat for tegra186-quill-p3310-1000-c03-00-base.dtb failed
是真正的错误。解决这个问题,你应该会很好。