我使用zabbix来监控网络设备。我的网络设备是思科交换机2960。当我使用OID从SNMP获取信息时 ifAdminStatus.10005(.1.3.6.1.2.1.2.2.1.7.10005)检查状态接口快速以太网0/5。我收到状态 up(1)。
但是当我运行命令#show ip interface brief时。结果是向下。结果如下:
SW_QTM#show ip int brief
Interface IP-Address OK? Method Status Protocol
Vlan1 unassigned YES NVRAM administratively down down
Vlan31 10.46.31.251 YES NVRAM up up
FastEthernet0/1 unassigned YES unset up up
FastEthernet0/2 unassigned YES unset up up
FastEthernet0/3 unassigned YES unset up up
FastEthernet0/4 unassigned YES unset up up
FastEthernet0/5 unassigned YES unset **down** down
FastEthernet0/6 unassigned YES unset down down
FastEthernet0/7 unassigned YES unset down down
FastEthernet0/8 unassigned YES unset up up
GigabitEthernet0/1 unassigned YES unset down down
为什么它有不同的价值?
请向我解释一下。
答案 0 :(得分:0)
ifOperStatus是您要查询的内容。此外,您确定索引10005是有问题的界面吗?