我想将两个太阳能逆变器的值存储在rrd中。我将modbus上的值作为绝对值(增加计数器)。我创建了这样的rrd:
rrdtool create -s 60 /data/solar.rrd --no-overwrite \
DS:WR1:COUNTER:300:0:U \
DS:WR2:COUNTER:300:0:U \
RRA:AVERAGE:0.5:1:43200 \
RRA:AVERAGE:0.5:5:25920 \
RRA:AVERAGE:0.5:60:8784 \
RRA:AVERAGE:0.5:1440:18993 \
RRA:MAX:0.5:1440:18993
使用一点Python,我使用(使用调试输出)将值插入此rrd:
rrdtool.update("/data/solar.rrd","-t","WR1:WR2","N:%i:%i" % (d1.inverter.WH,d2.inverter.WH))
info = rrdtool.info("/data/solar.rrd")
print "%i %i %i" % (info['last_update'],d1.inverter.WH,d2.inverter.WH)
循环运行:
user@machine:~# while(true); do sleep 60; ./get_data4rrd.py; done
1504028308 3521906 1870096
1504028369 3521911 1870097
1504028430 3521916 1870097
1504028491 3521921 1870098
1504028552 3521925 1870098
所以我希望对于DS WR1,我会得到4到6之间的值。但是在进行获取时它会有很大的不同:
user@machine:/data# rrdtool fetch solar.rrd AVERAGE -r 1m -s -15m
WR1 WR2
1504028400: 8.1857862607e-02 8.0323781910e-03
1504028460: 8.1857458806e-02 8.0440194250e-03
1504028520: 7.4102207109e-02 8.6226472416e-03
1504028580: 6.5478084175e-02 0.0000000000e+00
我知道rrdtool对齐我的输入以适应步长,但我仍然希望DS WR1的输出大约为4-6而不是0.08。
这里有什么问题?我无法弄清楚我的错误。
答案 0 :(得分:0)
手册页明确指出值始终存储为rate / s。如果您希望它是速率/步长,则需要乘以您的值:
CDEF:expection=DS,stepwidth,*
甚至更好,如果你想要kWh
CDEF:WR1kWh=WR1,3.6,*