ClickOnce应用程序中的DllNotFoundException

时间:2017-03-10 09:48:21

标签: c# wpf sqlite clickonce

我的WPF应用程序工作正常,但当我将其部署为ClickOnce应用程序时,它甚至无法启动。但是在Windows事件查看器中抛出了以下异常:

Application: Saito ERC-C.exe
Framework Version: v4.0.30319
Description: The process was terminated due to an unhandled exception.
Exception Info: System.DllNotFoundException
   at System.Data.SQLite.UnsafeNativeMethods.sqlite3_config_none(System.Data.SQLite.SQLiteConfigOpsEnum)
   at System.Data.SQLite.SQLite3.StaticIsInitialized()
   at System.Data.SQLite.SQLiteLog.Initialize()
   at System.Data.SQLite.SQLiteConnection..ctor(System.String, Boolean)
   at System.Data.SQLite.SQLiteConnection..ctor(System.String)
   at Saito_ERC_C.helpers.DBHelper.executeQuery(System.String)
   at Saito_ERC_C.LoginWindow..ctor()

Exception Info: System.Windows.Markup.XamlParseException
   at System.Windows.Markup.WpfXamlLoader.Load(System.Xaml.XamlReader, System.Xaml.IXamlObjectWriterFactory, Boolean, System.Object, System.Xaml.XamlObjectWriterSettings, System.Uri)
   at System.Windows.Markup.WpfXamlLoader.LoadBaml(System.Xaml.XamlReader, Boolean, System.Object, System.Xaml.Permissions.XamlAccessLevel, System.Uri)
   at System.Windows.Markup.XamlReader.LoadBaml(System.IO.Stream, System.Windows.Markup.ParserContext, System.Object, Boolean)
   at System.Windows.Application.LoadBamlStreamWithSyncInfo(System.IO.Stream, System.Windows.Markup.ParserContext)
   at System.Windows.Application.LoadComponent(System.Uri, Boolean)
   at System.Windows.Application.DoStartup()
   at System.Windows.Application.<.ctor>b__1_0(System.Object)
   at System.Windows.Threading.ExceptionWrapper.InternalRealCall(System.Delegate, System.Object, Int32)
   at System.Windows.Threading.ExceptionWrapper.TryCatchWhen(System.Object, System.Delegate, System.Object, Int32, System.Delegate)
   at System.Windows.Threading.DispatcherOperation.InvokeImpl()
   at System.Windows.Threading.DispatcherOperation.InvokeInSecurityContext(System.Object)
   at System.Threading.ExecutionContext.RunInternal(System.Threading.ExecutionContext, System.Threading.ContextCallback, System.Object, Boolean)
   at System.Threading.ExecutionContext.Run(System.Threading.ExecutionContext, System.Threading.ContextCallback, System.Object, Boolean)
   at System.Threading.ExecutionContext.Run(System.Threading.ExecutionContext, System.Threading.ContextCallback, System.Object)
   at MS.Internal.CulturePreservingExecutionContext.Run(MS.Internal.CulturePreservingExecutionContext, System.Threading.ContextCallback, System.Object)
   at System.Windows.Threading.DispatcherOperation.Invoke()
   at System.Windows.Threading.Dispatcher.ProcessQueue()
   at System.Windows.Threading.Dispatcher.WndProcHook(IntPtr, Int32, IntPtr, IntPtr, Boolean ByRef)
   at MS.Win32.HwndWrapper.WndProc(IntPtr, Int32, IntPtr, IntPtr, Boolean ByRef)
   at MS.Win32.HwndSubclass.DispatcherCallbackOperation(System.Object)
   at System.Windows.Threading.ExceptionWrapper.InternalRealCall(System.Delegate, System.Object, Int32)
   at System.Windows.Threading.ExceptionWrapper.TryCatchWhen(System.Object, System.Delegate, System.Object, Int32, System.Delegate)
   at System.Windows.Threading.Dispatcher.LegacyInvokeImpl(System.Windows.Threading.DispatcherPriority, System.TimeSpan, System.Delegate, System.Object, Int32)
   at MS.Win32.HwndSubclass.SubclassWndProc(IntPtr, Int32, IntPtr, IntPtr)
   at MS.Win32.UnsafeNativeMethods.DispatchMessage(System.Windows.Interop.MSG ByRef)
   at System.Windows.Threading.Dispatcher.PushFrameImpl(System.Windows.Threading.DispatcherFrame)
   at System.Windows.Threading.Dispatcher.PushFrame(System.Windows.Threading.DispatcherFrame)
   at System.Windows.Application.RunDispatcher(System.Object)
   at System.Windows.Application.RunInternal(System.Windows.Window)
   at System.Windows.Application.Run(System.Windows.Window)
   at Saito_ERC_C.App.Main()

我认为有些sqlite dll可能会丢失,所以我以这种方式修改了Application Files而没有任何成功。

Application Files

我该如何解决这个问题?

1 个答案:

答案 0 :(得分:1)

经过数小时的努力,我找到了解决方案。 (see )

在我的项目根目录中创建了名为x64,x86的文件夹,然后分别从SQLite.Interop.dllbin\Release\x64文件夹添加了bin\Release\x64文件。

然后它在部署后起作用了。