I have also asked this question @ the Lazarus forums, here
我试图通过TProcess与Octave通信,但我似乎无法从中读取任何字节。附件是主要形式的单位;在我的帖子下,论坛上有一个完整的演示应用程序。
unit Unit1;
{$mode objfpc}{$H+}
interface
uses
Classes, SysUtils, FileUtil, Forms, Controls, Graphics, Dialogs, StdCtrls, Process;
type
{ TForm1 }
TForm1 = class(TForm)
Button1: TButton;
Button2: TButton;
procedure Button1Click(Sender: TObject);
procedure Button2Click(Sender: TObject);
private
{ private declarations }
public
{ public declarations }
end;
var
Form1: TForm1;
POctave: TProcess;
implementation
{$R *.lfm}
{ TForm1 }
procedure TForm1.Button1Click(Sender: TObject);
begin
if (not POctave.Running) then
begin
POctave.Executable := 'C:\Octave\Octave-4.2.0\bin\octave-cli.exe';
POctave.Parameters.Add('--no-gui');
POctave.Options := [poUsePipes];
WriteLn('-- Executing octave --');
POctave.Execute;
end;
end;
procedure TForm1.Button2Click(Sender: TObject);
var
command: string;
Buffer: string;
BytesAvailable: DWord;
BytesRead: longint;
NoMoreOutput: boolean;
begin
command := 'pwd' + #10;
if (POctave.Running) then
POctave.Input.Write(command, Length(command));
if (POctave.Running) then
begin
BytesAvailable := POctave.Output.NumBytesAvailable;
BytesRead := 0;
while BytesAvailable > 0 do
begin
SetLength(Buffer, BytesAvailable);
BytesRead := POctave.OutPut.Read(Buffer[1], BytesAvailable);
WriteLn(Buffer);
BytesAvailable := POctave.Output.NumBytesAvailable;
NoMoreOutput := False;
end;
end;
end;
initialization
POctave := TProcess.Create(nil);
finalization
POctave.Free;
end.
我添加了睡眠例程,并将'pwd'命令的返回更改为#1310,两者均未成功。
procedure TForm1.Button2Click(Sender: TObject);
var
command: ansistring;
Buffer: string;
BytesAvailable: DWord;
BytesRead: longint;
NoMoreOutput: boolean;
begin
command := 'pwd'#13#10;
if (POctave.Running) then
POctave.Input.Write(command, Length(command));
Sleep(100);
if (POctave.Running) then
begin
Sleep(100);
BytesAvailable := POctave.Output.NumBytesAvailable;
BytesRead := 0;
while BytesAvailable > 0 do
begin
Sleep(100);
SetLength(Buffer, BytesAvailable);
BytesRead := POctave.OutPut.Read(Buffer[1], BytesAvailable);
WriteLn(Buffer);
BytesAvailable := POctave.Output.NumBytesAvailable;
NoMoreOutput := False;
end;
end;
end;
答案 0 :(得分:1)
问题是我在说这句话:
POctave.Input.Write(command, Length(command));
而不是:
POctave.Input.Write(command[1], Length(command));
更改后(并添加延迟!等待结果绝对至关重要,但我的错误更为根本。)
请记住:Pascal字符串不是C字符串。糟糕...
有效!现在我可以向Octave发送命令并通过管道检索结果。 :)