以下简单的VBS示例从WMI中检索CPU标题,体系结构和系列:
s = ""
For Each Item In GetObject("winmgmts:{impersonationLevel=impersonate}!\\.\Root\CIMV2").InstancesOf("Win32_Processor")
s = s & "Caption = " & Item.Caption & vbCrLf
s = s & "Architecture = " & Item.Architecture & vbCrLf
s = s & "Family = " & Item.Family & vbCrLf
Next
WScript.Echo s
我的输出是:
Caption = Intel64 Family 6 Model 42 Stepping 7
架构= 9
家庭= 198
我想要的是为架构和系列而不是索引检索更多描述性值。这些属性具有Values
限定符,它指定属性的可能值列表,以及ValueMap
限定符,它指定Values
中相应字符串值的整数值。这些限定符显示在我用两个实用程序制作的屏幕截图中:
WMI代码创建器
WMI CIM Studio
在最后一个屏幕截图中,您可以看到Win32_Processor
类,Architecture
属性,Values
限定符,其中包含六个字符串的数组:x86, MIPS, Alpha, PowerPC, ia64, x64
,它对应于数组中的索引在ValueMap
限定符中:0, 1, 2, 3, 6, 9
。但是,以下代码不会枚举WMI CIM Studio中标记为已修改的限定符,例如Description
和Values
,原因不明:
Set objClass = GetObject("winmgmts:{impersonationLevel=impersonate}!\\.\root\CIMV2:Win32_Processor")
s = ""
For Each objQualifier In objClass.Properties_("Architecture").Qualifiers_
s = s & objQualifier.Name & " = "
If IsArray(objQualifier.Value) Then
s = s & "{" & Join(objQualifier.Value, ", ") & "}"
Else
s = s & objQualifier.Value
End If
s = s & vbCrLf
Next
WScript.Echo s
我尝试在x64和x86主机上运行它,并返回相同的输出,如下所示:
CIMTYPE = uint16
MappingStrings = {WMI}
读=真
ValueMap = {0,1,2,3,6,9}
虽然我期待:
CIMTYPE = uint16
Description = Architecture属性指定此平台使用的处理器体系结构。它返回以下整数值之一:
0 - x86
1 - MIPS
2 - 阿尔法 3 - PowerPC
6 - ia64
9 - x64
MappingStrings = {WMI}
读=真
ValueMap = {0,1,2,3,6,9}
值= {x86,MIPS,Alpha,PowerPC,ia64,x64}
我怎样才能获得这些资格赛?还有其他方法可以检索它们吗?
更新
我已经设法获得所有属性限定符,包括修改,感谢@ Kul-Tigin指出我正确的方向并提供链接。有权访问限定符,我从类中提取Values
和ValueMap
数组,并创建一种转换表oMap
,用于将整数属性值转换为关联的字符串:
Const wbemFlagUseAmendedQualifiers = 131072
Set oService = GetObject("winmgmts:{impersonationLevel=impersonate}!\\.\Root\CIMV2")
s = ""
For Each oInstance In oService.InstancesOf("Win32_Processor")
For Each sName In Array("Caption", "Family")
s = s & sName & " = " & oInstance.Properties_.Item(sName).Value & vbCrLf
Next
Next
s = s & vbCrLf
Set oClass = oService.Get("Win32_Processor", wbemFlagUseAmendedQualifiers)
Set oProperty = oClass.Properties_.Item("Family")
aValues = oProperty.Qualifiers_.Item("Values")
aValueMap = oProperty.Qualifiers_.Item("ValueMap")
Set oMap = CreateObject("Scripting.Dictionary")
For i = 0 To UBound(aValues)
oMap(aValueMap(i)) = aValues(i)
Next
For Each sKey In oMap
s = s & sKey & " = " & oMap(sKey) & vbCrLf
Next
WScript.Echo s
我的输出如下:
Caption = Intel64 Family 6 Model 42 Stepping 7
Family = 198
1 = Other
2 = Unknown
3 = 8086
4 = 80286
5 = 80386
6 = 80486
7 = 8087
8 = 80287
9 = 80387
10 = 80487
11 = Pentium(R) brand
12 = Pentium(R) Pro
13 = Pentium(R) II
14 = Pentium(R) processor with MMX(TM) technology
15 = Celeron(TM)
16 = Pentium(R) II Xeon(TM)
17 = Pentium(R) III
18 = M1 Family
19 = M2 Family
24 = K5 Family
25 = K6 Family
26 = K6-2
27 = K6-3
28 = AMD Athlon(TM) Processor Family
29 = AMD(R) Duron(TM) Processor
30 = AMD29000 Family
31 = K6-2+
32 = Power PC Family
33 = Power PC 601
34 = Power PC 603
35 = Power PC 603+
36 = Power PC 604
37 = Power PC 620
38 = Power PC X704
39 = Power PC 750
48 = Alpha Family
49 = Alpha 21064
50 = Alpha 21066
51 = Alpha 21164
52 = Alpha 21164PC
53 = Alpha 21164a
54 = Alpha 21264
55 = Alpha 21364
64 = MIPS Family
65 = MIPS R4000
66 = MIPS R4200
67 = MIPS R4400
68 = MIPS R4600
69 = MIPS R10000
80 = SPARC Family
81 = SuperSPARC
82 = microSPARC II
83 = microSPARC IIep
84 = UltraSPARC
85 = UltraSPARC II
86 = UltraSPARC IIi
87 = UltraSPARC III
88 = UltraSPARC IIIi
96 = 68040
97 = 68xxx Family
98 = 68000
99 = 68010
100 = 68020
101 = 68030
112 = Hobbit Family
120 = Crusoe(TM) TM5000 Family
121 = Crusoe(TM) TM3000 Family
122 = Efficeon(TM) TM8000 Family
128 = Weitek
130 = Itanium(TM) Processor
131 = AMD Athlon(TM) 64 Processor Family
132 = AMD Opteron(TM) Family
144 = PA-RISC Family
145 = PA-RISC 8500
146 = PA-RISC 8000
147 = PA-RISC 7300LC
148 = PA-RISC 7200
149 = PA-RISC 7100LC
150 = PA-RISC 7100
160 = V30 Family
176 = Pentium(R) III Xeon(TM)
177 = Pentium(R) III Processor with Intel(R) SpeedStep(TM) Technology
178 = Pentium(R) 4
179 = Intel(R) Xeon(TM)
180 = AS400 Family
181 = Intel(R) Xeon(TM) processor MP
182 = AMD AthlonXP(TM) Family
183 = AMD AthlonMP(TM) Family
184 = Intel(R) Itanium(R) 2
185 = Intel Pentium M Processor
190 = K7
200 = IBM390 Family
201 = G4
202 = G5
203 = G6
204 = z/Architecture base
250 = i860
251 = i960
260 = SH-3
261 = SH-4
280 = ARM
281 = StrongARM
300 = 6x86
301 = MediaGX
302 = MII
320 = WinChip
350 = DSP
500 = Video Processor
我也尝试了另一台PC上的代码:
Caption = AMD64 Family 21 Model 56 Stepping 1
Family = 72
...
有关MSDN about Standard Qualifiers用法的详细信息:
ValueMap
此限定符可以单独使用,也可以与Values限定符结合使用。与Values限定符结合使用时,ValueMap数组中值的位置提供Values数组中相应条目的位置。仅将ValueMap限定符与字符串和整数值一起使用。在值映射数组中表示整数值的语法是[+ | =] digit [* digit]。内容,最大位数和表示的值受关联属性的类型约束。例如,uint8可能没有签名,必须少于四位,并且必须表示小于256的值
值
此属性还指定要映射到枚举属性的字符串值数组。此限定符可以应用于整数属性或字符串属性,映射可以是隐式或显式的。如果映射是隐式的,则整数或字符串属性值表示Values数组中的序号位置。如果映射是显式的,则该属性必须是整数,并且有效的属性值将在ValueMap限定符定义的数组中列出。有关更多信息,请参阅值映射 如果不存在ValueMap限定符,则通过使用关联属性,方法返回类型或方法参数中的值来索引Values数组(零相对)。如果存在ValueMap限定符,则值index由值映射中的属性值的位置定义。
现在我一直在检索相应的字符串,因为198
限定符中既没有72
也没有ValueMap
这样的索引。
答案 0 :(得分:0)
答案是,Values
/ ValueMap
限定符字符串表不完整且无法使用。如果要将每个索引映射到字符串值,则必须自己创建此表。
Family
类的Win32_Processor
属性的值来自处理器信息 SMBIOS结构。值由specification定义(最新文档截至2018年1月),第46页的表包含所需的字符串:
198 - 英特尔®酷睿™i7处理器
72 - AMD A系列处理器
使用此数据,您可以创建字符串表并将其维护为新的SMBIOS版本中引入的新处理器类型。
可以找到C ++枚举形式的类似数据here。