我正在尝试在Weblogic 12c上启动托管服务器。我已按照documentation from Oracle执行此操作,除最后一步外,每一步都有效。也就是说,我启动了一个管理服务器,并成功启动了一个节点管理器。但是,当我使用节点管理器启动托管服务器时,事情就会出错。在控制台中,我的托管服务器的状态显示为“FAILED_NOT_RESTARTABLE”,并且上次操作的状态为“FAILED”。
以下是报告错误的日志:
<Jul 21, 2016 2:51:42 PM EDT> <Info> <Management> <BEA-141107> <Version: WebLogic Server 12.2.1.0.0 Tue Oct 6 10:05:47 PDT 2015 1721936>
<Jul 21, 2016 2:51:46 PM EDT> <Notice> <WebLogicServer> <BEA-000365> <Server state changed to STARTING.>
<Jul 21, 2016 2:51:46 PM EDT> <Info> <WorkManager> <BEA-002900> <Initializing self-tuning thread pool.>
<Jul 21, 2016 2:51:46 PM EDT> <Info> <WorkManager> <BEA-002942> <CMM memory level becomes 0. Setting standby thread pool size to 256.>
<Jul 21, 2016 2:51:47 PM EDT> <Critical> <WebLogicServer> <BEA-000362> <Server failed. Reason: [Server:002653]The servers administration channel conflicts with the Administration Servers channel.>
<Jul 21, 2016 2:51:47 PM EDT> <Notice> <WebLogicServer> <BEA-000365> <Server state changed to FAILED.>
<Jul 21, 2016 2:51:47 PM EDT> <Error> <WebLogicServer> <BEA-000383> <A critical service failed. The server will shut itself down.>
我使用的所有设置都是默认设置。托管服务器和管理服务器的默认端口为“9002”。我试过四处寻找,并改变其中一个或另一个值,但无济于事。
答案 0 :(得分:1)
您应该默认启用域管理端口9002。您可以将其禁用或使用其他端口作为管理通道,也可以使用其他端口作为受管服务器