我尝试将NodeMCU与IBM Bluemix IoT Foundation连接起来。不安全的MQTT连接非常出色,可以将数据从BMP180推送到云端。但是,当我开始使用TLS时,它将无法连接到代理。我尝试与mqtt.fx建立TLS连接并且工作正常,看起来NodeMCU就是问题所在。 如果我运行此代码:
orgID="****"
BROKER = orgID..".<bluemix>"
BRPORT = 8883
CLIENTID = "d:"..orgID..":generic_esp:generic_esp_01"
print("ClientID: "..CLIENTID)
BRPWD = "***********"
BRUSER = "use-token-auth"
local function publish()
dofile('sensor.lc')
m:publish('iot-2/evt/esp8266/fmt/json',payload,1,0,
function(conn) print('Payload published') end)
end
m = mqtt.Client(CLIENTID, 120, BRUSER, BRPWD)
c = false
print('MQTT Init')
m:on('offline', function(con) print('mqtt offline'); c = false end)
m:connect(BROKER, BRPORT, 1, function(conn)
print('MQTT connected: '..BROKER..':'..BRPORT)
c = true
publish()
end)
tmr.alarm(1, 1000, 1, function()
if not c then
print('MQTT reconnecting')
m:close()
c = false
m:connect(BROKER, BRPORT, 1, function(conn) print('.. MQTT reconnected: '..BROKER..':'..BRPORT); c = true end)
end
if c then
publish()
end
end)
esp8266只是打印“MQTT重新连接”而无法连接。 我的代码有问题,或者在NodeMCU 1.4中没有完全支持TLS吗?
答案 0 :(得分:2)
我在我们的一个测试台上抓住了你的客户问候:
<00> 0000 16 03 02 00 33 01 00 00 2f 03 02 00 00 00 00 d0 0010 b1 a1 3a 07 1c 1b 3e f2 fc 03 91 d6 18 b5 ae 5d 0020 77 65 37 f5 07 10 45 d1 7e 1a ea 00 00 08 00 2f 0030 00 35 00 05 00 04 01 00这看起来像是TLS v1。 1 客户端问候。通常客户会用它可以做的“最好”打招呼并向下协商。在这种情况下,IoTF将简单地关闭连接,因为它仅支持TLS 1.2。请问您是否可以检查您的设备是否设置为执行TLS 1.2?