我正在尝试使用Jquery和Ajax中的WebMethod在Gridview中显示数据。我在SQL Server数据库中使用存储过程进行分页并返回每页数据。当在浏览器上呈现页面时没有显示数据但是jquery的alert()函数被触发,表明我收到错误。在单击inspect元素时,我看到错误是 - “无法加载资源:服务器响应状态为500(内部服务器错误)”
Aspx Page
<asp:Content ID="Content1" ContentPlaceHolderID="head" Runat="Server">
<style type="text/css">
body
{
font-family: Arial;
font-size: 10pt;
}
.Pager span
{
text-align: center;
color: #999;
display: inline-block;
width: 20px;
background-color: #A1DCF2;
margin-right: 3px;
line-height: 150%;
border: 1px solid #3AC0F2;
}
.Pager a
{
text-align: center;
display: inline-block;
width: 20px;
background-color: #3AC0F2;
color: #fff;
border: 1px solid #3AC0F2;
margin-right: 3px;
line-height: 150%;
text-decoration: none;
}
</style>
<script type="text/javascript" src="http://ajax.googleapis.com/ajax/libs/jquery/1.8.3/jquery.min.js"></script>
<script src="js/ASPSnippets_Pager.min.js" type="text/javascript"></script>
<script type="text/javascript">
$(function () {
GetABC(1);
});
$(".Pager .page").live("click", function () {
GetABC(parseInt($(this).attr('page')));
});
function GetABC(pageIndex) {
$.ajax({
type: "POST",
url: "ABC.aspx/GetABC",
data: '{pageIndex: ' + pageIndex + '}',
contentType: "application/json; charset=utf-8",
dataType: "json",
success: OnSuccess,
failure: function (response) {
alert("Failure");
},
error: function (response) {
alert("Error");
}
});
}
function OnSuccess(response) {
var xmlDoc = $.parseXML(response.d);
var xml = $(xmlDoc);
var xyz = xml.find("table1");
var row = $("[id*=GridView1] tr:last-child").clone(true);
$("[id*=GridView1] tr").not($("[id*=GridView1] tr:first-child")).remove();
$.each(xyz, function () {
var abc= $(this);
$("td", row).eq(0).html($(this).find("XXX").text());
$("td", row).eq(1).html($(this).find("XXX").text());
$("td", row).eq(2).html($(this).find("XXX").text());
$("td", row).eq(3).html($(this).find("XXX").text());
$("td", row).eq(4).html($(this).find("XXX").text());
$("td", row).eq(5).html($(this).find("XXX").text());
$("td", row).eq(6).html($(this).find("XXX").text());
$("td", row).eq(7).html($(this).find("XXX").text());
$("[id*=GridView1]").append(row);
row = $("[id*=GridView1] tr:last-child").clone(true);
});
var pager = xml.find("Pager");
$(".Pager").ASPSnippets_Pager({
ActiveCssClass: "current",
PagerCssClass: "pager",
PageIndex: parseInt(pager.find("PageIndex").text()),
PageSize: parseInt(pager.find("PageSize").text()),
RecordCount: parseInt(pager.find("RecordCount").text())
});
};
</script>
</asp:Content>
<asp:Content ID="Content2" ContentPlaceHolderID="ContentPlaceHolder1" Runat="Server">
<asp:GridView ID="GridView1" runat="server" AutoGenerateColumns="False"
RowStyle-BackColor="#A1DCF2" HeaderStyle-BackColor="#3AC0F2"
HeaderStyle-ForeColor="White">
<Columns>
<asp:BoundField ItemStyle-Width="150px" HeaderText="XXX" DataField="XXX" />
<asp:BoundField ItemStyle-Width="150px" HeaderText="XXX" DataField="XXX" />
<asp:BoundField ItemStyle-Width="150px" HeaderText="XXX" DataField="XXX" />
<asp:BoundField ItemStyle-Width="150px" HeaderText="XXX" DataField="XXX" />
<asp:BoundField ItemStyle-Width="200px" HeaderText="XXX" DataField="XXX" />
<asp:BoundField ItemStyle-Width="150px" HeaderText="XXX" DataField="XXX" />
<asp:BoundField ItemStyle-Width="5px" HeaderText="XXX" DataField="XXX" />
<asp:BoundField ItemStyle-Width="5px" HeaderText="XXX" DataField="XXX" />
</Columns>
</asp:GridView>
<br />
<div class="Pager"></div>
</asp:Content>
CS页面
using System;
using System.Collections.Generic;
using System.Linq;
using System.Web;
using System.Web.UI;
using System.Web.UI.WebControls;
using System.Data;
using System.Configuration;
using System.Data.SqlClient;
using System.Web.Services;
public partial class ABC: System.Web.UI.Page
{
private static int PageSize = 10;
protected void Page_Load(object sender, EventArgs e)
{
if (!IsPostBack)
{
BindGrid();
}
}
private void BindGrid()
{
DataTable dt = new DataTable();
dt.Columns.Add("xxx");
dt.Columns.Add("xxx");
dt.Columns.Add("xxx");
dt.Columns.Add("xxx");
dt.Columns.Add("xxx");
dt.Columns.Add("xxx");
dt.Columns.Add("xxx");
dt.Columns.Add("xxx");
dt.Rows.Add();
GridView1.DataSource = dt;
GridView1.DataBind();
}
[WebMethod]
public static string GetABC(int PageIndex)
{
string query = "[GetABC_Pager]";
SqlCommand cmd = new SqlCommand(query);
cmd.CommandType = CommandType.StoredProcedure;
cmd.Parameters.AddWithValue("@PageIndex", PageIndex);
cmd.Parameters.AddWithValue("@PageSize", PageSize);
cmd.Parameters.Add("@RecordCount", SqlDbType.Int, 4).Direction = ParameterDirection.Output;
return GetData(cmd, PageIndex).GetXml();
}
private static DataSet GetData(SqlCommand cmd, int pageIndex)
{
string strConnstring = ConfigurationManager.ConnectionStrings["myconnection"].ConnectionString;
using (SqlConnection con = new SqlConnection(strConnstring))
{
using (SqlDataAdapter sda = new SqlDataAdapter())
{
cmd.Connection = con;
sda.SelectCommand = cmd;
using (DataSet ds = new DataSet())
{
sda.Fill(ds, "table1");
DataTable dt = new DataTable("Pager");
dt.Columns.Add("PageIndex");
dt.Columns.Add("PageSize");
dt.Columns.Add("RecordCount");
dt.Rows.Add();
dt.Rows[0]["PageIndex"] = pageIndex;
dt.Rows[0]["PageSize"] = PageSize;
dt.Rows[0]["RecordCount"] = cmd.Parameters["@RecordCount"].Value;
ds.Tables.Add(dt);
return ds;
}
}
}
}
}
页面加载警报(“错误”)函数被触发并且gridview中没有数据。当我在我的Localhost上运行时,相同的代码没有显示错误,但是当我将相同的文件传输到我的服务器时,我收到此错误。请指导我做错的地方,我还需要做其他事情。我已按照本文开发此应用程序 - http://www.aspsnippets.com/Articles/Retrieve-data-from-Database-and-display-on-page-using-jQuery-AJAX-in-ASPNet.aspx