我做了一些谷歌,并没有“设备附加”错误与事件日志有任何关系。我也在Micosoft fourm发布了问题,但没有回复。以为我会给你们一个机会。这里是问题的链接。 https://social.msdn.microsoft.com/Forums/en-US/d484d9dc-d9eb-4d19-97b8-9ae4db63e041/systemdiagnosticseventlog-a-device-attached-to-the-system-is-not-functioning?forum=netfxbcl
以下是错误消息:
System.ComponentModel.Win32Exception was caught
ErrorCode=-2147467259
HResult=-2147467259
Message=A device attached to the system is not functioning
NativeErrorCode=31
Source=System
StackTrace:
at System.Diagnostics.EventLogInternal.InternalWriteEvent(UInt32 eventID, UInt16 category, EventLogEntryType type, String[] strings, Byte[] rawData, String currentMachineName)
at System.Diagnostics.EventLogInternal.WriteEntry(String message, EventLogEntryType type, Int32 eventID, Int16 category, Byte[] rawData)
at System.Diagnostics.EventLog.WriteEntry(String message, EventLogEntryType type)
at VB_Braums_ClassLib.LogIt.WriteEventLog(String Entry, EventLogEntryType eventType, String Source) in \\Corp01\Vol1\Mis\Pccode\Ms.net\ProductionLibs\ProductionLibs\ProdLibCommon.vb:line 3666
InnerException:
此代码位于库中,因此我创建了一个“hello world”来演示该问题。我会在最后发布。这个.net 4框架已经在我们的代码中存在了一段时间。我们开始从XP升级到Win 7.基本上,事件日志大小限制为32667号码。所以我们进行了测试,如果字符串大于那个,那么我们将把它写成32000字节的卡盘。在两个不同的win7框中,我们收到“设备附加”错误消息。在XP机器上运行相同的代码,它的工作原理。哦,Win 7盒子是64位。我想知道胜利7 32位是否会有同样的问题?其他人可以复制它吗? tmpsize似乎是不同的数字,但如果你玩它,你可以把它降到数字x作品和(x + 1)没有。介于30000和32000之间。从大多数snighfict价值开始并向下移动,我打赌它在31000 - 31900范围内。
Module Module1
Sub Main()
Dim logName As String = "BraumsLog"
Dim objEventLog As New System.Diagnostics.EventLog()
Dim needCreate As Boolean = False
Dim Source As String = ""
If Source.Length = 0 Then Source = "Test"
Dim Entry As String = "".PadLeft(64000, "1"c)
'Register the App as an Event Source
If EventLog.SourceExists(Source) Then
Dim slog As String = EventLog.LogNameFromSourceName(Source, ".")
If slog <> logName Then EventLog.DeleteEventSource(Source) : needCreate = True
Else
needCreate = True
End If
If needCreate Then EventLog.CreateEventSource(Source, logName)
objEventLog.Source = Source
'*************************************
'*********** New Code ****************
objEventLog.MaximumKilobytes = 20480
objEventLog.ModifyOverflowPolicy(OverflowAction.OverwriteAsNeeded, 0)
'*************************************
'*************************************
'WriteEntry is overloaded; this is one
'of 10 ways to call it
Dim tmp As String = ""
Dim tmpSize As Integer = 32000 '31890 works 31891 does not
Do While Entry.Length > tmpSize
tmp = Entry.Substring(0, tmpSize - 1)
objEventLog.WriteEntry(tmp, EventLogEntryType.Information)
Debug.WriteLine(tmp.Length.ToString)
Entry = Entry.Substring(tmpSize)
Loop
tmp = Entry
objEventLog.WriteEntry(tmp, EventLogEntryType.Information)
End Sub
End Module
答案 0 :(得分:3)
我们目前也遇到了这个问题。我不确定这是否是解决方案,关于此错误的官方信息是关于软盘而不是日志消息: https://technet.microsoft.com/en-us/library/cc978749.aspx
但是我发现在Log4Net上报告了一个错误,当写入大约30.000个字符的日志消息时,日志文件可能会损坏。 https://issues.apache.org/jira/browse/LOG4NET-360
我们现在将重新创建日志文件并在写入新日志条目之前剪切字符串。手指交叉,这有助于(评论赞赏)。
答案 1 :(得分:0)
我做了与Dess所说的相同的事情,当我将最大日志条目大小减小到25000个字符时,它对我有用。
先前的消息A device attached to the system is not functioning
似乎具有误导性。