所以我有一个完整的Product.wxs文件,可以安装一个漂亮的Signature绘图程序。我添加了一个带有TestClass的TestLibrary项目,其中包含一个非常基本的Add(int,int)方法,并在我的程序中用它来进行测试,然后用热量收集类的目录(并运行它和XSLT文件进行格式化) ,将Output.wxs链接到项目,引用ComponentGroup,并尝试将整个事物安装在一起,希望将安装该类,并且软件可以运行。情况并非如此,它的构建和安装完美无缺,只是因为安装的.exe在启动时失败。
这是Product.wxs:
<?xml version="1.0" encoding="utf-8"?>
<Wix xmlns="http://schemas.microsoft.com/wix/2006/wi">
<Product Id="6daf7a49-43a8-403b-8d15-96197c8751cc" Name="SetupProject_Sig" Language="1033" Version="1.0.0.0" Manufacturer="VTC" UpgradeCode="f2ad826c-59b9-4f9f-af0d-8c9d80030605">
<Package InstallerVersion="200" Compressed="yes" InstallScope="perMachine" />
<Condition Message="You need to be an administrator to install this product.">
Privileged
</Condition>
<MajorUpgrade DowngradeErrorMessage="A newer version of [ProductName] is already installed." />
<MediaTemplate />
<Feature Id="ProductFeature" Title="SetupProject_Sig" Level="1">
<ComponentGroupRef Id="ProductComponents" />
<ComponentGroupRef Id="ComComponents" />
</Feature>
<Property Id="ApplicationFolderName" Value="Signature" />
<Property Id="WixAppFolder" Value="WixPerMachineFolder" />
<WixVariable Id="WixUISupportPerUser" Value="1" Overridable="yes" />
<WixVariable Id="WixUISupportPerMachine" Value="1" Overridable="yes" />
<Property Id="WIXUI_INSTALLDIR" Value="APPLICATIONFOLDER" />
</Product>
<Fragment>
<Directory Id="TARGETDIR" Name="SourceDir">
<Directory Id="ProgramFilesFolder">
<Directory Id="APPLICATIONFOLDER" Name="SetupProject_Sig" />
</Directory>
</Directory>
</Fragment>
<Fragment>
<Feature Id="Complete" Title="Signature Tosz 1.0" Description="All files." Level="1" Display="expand" ConfigurableDirectory="APPLICATIONFOLDER">
<Feature Id="MainProgram" Title="Program" Description="The main executable." Level="1">
<ComponentRef Id="MainExecutable" />
<ComponentRef Id="HelperLibrary" />
<ComponentRef Id="ProgramMenuDir" />
</Feature>
<Feature Id="Documentation" Title="Description" Description="Instruction manual." Level="1000">
<ComponentRef Id="Manual" />
<Condition Level="1">FILEEXISTS</Condition>
</Feature>
</Feature>
</Fragment>
<Fragment>
<ComponentGroup Id="ProductComponents" Directory="APPLICATIONFOLDER">
<Component Id="ProductComponent" Guid="b3594fac-7524-4529-8874-5811705996b8">
<File Source="$(var.Control_Sig.TargetPath)" />
</Component>
</ComponentGroup>
</Fragment>
<Fragment>
<DirectoryRef Id="TARGETDIR">
<Component Id="RegistryComp">
<RegistryKey Id="ToszRegApplicationfolder" Root="HKLM" Key="Software\VTC\Tosz 1.0" Action="createAndRemoveOnUninstall">
<RegistryValue Type="string" Name="APPLICATIONFOLDER" Value="[APPLICATIONFOLDER]" />
<RegistryValue Type="integer" Name="Flag" Value="0" />
</RegistryKey>
</Component>
</DirectoryRef>
</Fragment>
</Wix>
预制热量命令:
call "%wix%\bin\heat.exe" dir "$(SolutionDir)\TestLibrary\bin\Debug" -var "var.TargetDir" -gg -g1 -srd -cg ComComponents -template fragment -out "$(ProjectDir)\Output.wxs" -v -t "$(ProjectDir)\bin\Debug\Filter.xslt"
Output.wxs
<?xml version="1.0" encoding="utf-8"?>
<Wix xmlns="http://schemas.microsoft.com/wix/2006/wi">
<Fragment>
<DirectoryRef Id="TARGETDIR" />
</Fragment>
<Fragment>
<ComponentGroup Id="ComComponents">
<Component Id="cmp278E5D4E5835479434800F8B4056EB4B" Directory="TARGETDIR" Guid="A09371FD-ACE5-474E-B1B8-D9C83CF05497">
<Class Id="{DB173953-D21D-3F29-BC10-C6299EBD2BFF}" Context="InprocServer32" Description="TestLibrary.TestClass" ThreadingModel="both" ForeignServer="mscoree.dll">
<ProgId Id="TestLibrary.TestClass" Description="TestLibrary.TestClass" />
</Class>
<File Id="fil296E15219B07AF9559E0660E87293FC3" KeyPath="yes" Source="$(var.TargetDir)\TestLibrary.dll" />
<RegistryValue Root="HKCR" Key="CLSID\{DB173953-D21D-3F29-BC10-C6299EBD2BFF}\Implemented Categories\{62C8FE65-4EBB-45e7-B440-6E39B2CDBF29}" Value="" Type="string" Action="write" />
<RegistryValue Root="HKCR" Key="CLSID\{DB173953-D21D-3F29-BC10-C6299EBD2BFF}\InprocServer32\1.0.0.0" Name="Class" Value="TestLibrary.TestClass" Type="string" Action="write" />
<RegistryValue Root="HKCR" Key="CLSID\{DB173953-D21D-3F29-BC10-C6299EBD2BFF}\InprocServer32\1.0.0.0" Name="Assembly" Value="TestLibrary, Version=1.0.0.0, Culture=neutral, PublicKeyToken=null" Type="string" Action="write" />
<RegistryValue Root="HKCR" Key="CLSID\{DB173953-D21D-3F29-BC10-C6299EBD2BFF}\InprocServer32\1.0.0.0" Name="RuntimeVersion" Value="v4.0.30319" Type="string" Action="write" />
<RegistryValue Root="HKCR" Key="CLSID\{DB173953-D21D-3F29-BC10-C6299EBD2BFF}\InprocServer32\1.0.0.0" Name="CodeBase" Value="file:///[#fil296E15219B07AF9559E0660E87293FC3]" Type="string" Action="write" />
<RegistryValue Root="HKCR" Key="CLSID\{DB173953-D21D-3F29-BC10-C6299EBD2BFF}\InprocServer32" Name="Class" Value="TestLibrary.TestClass" Type="string" Action="write" />
<RegistryValue Root="HKCR" Key="CLSID\{DB173953-D21D-3F29-BC10-C6299EBD2BFF}\InprocServer32" Name="Assembly" Value="TestLibrary, Version=1.0.0.0, Culture=neutral, PublicKeyToken=null" Type="string" Action="write" />
<RegistryValue Root="HKCR" Key="CLSID\{DB173953-D21D-3F29-BC10-C6299EBD2BFF}\InprocServer32" Name="RuntimeVersion" Value="v4.0.30319" Type="string" Action="write" />
<RegistryValue Root="HKCR" Key="CLSID\{DB173953-D21D-3F29-BC10-C6299EBD2BFF}\InprocServer32" Name="CodeBase" Value="file:///[#fil296E15219B07AF9559E0660E87293FC3]" Type="string" Action="write" />
</Component>
<Component Id="cmp5BD81C93D46AA48BFAA1819DF54A67EB" Directory="TARGETDIR" Guid="86402057-DA0F-4B8E-BD0B-4973739A4008">
<File Id="fil108FAB265F126BACEED88B56AB065A99" KeyPath="yes" Source="$(var.TargetDir)\TestLibrary.tlb">
<TypeLib Id="{A9413C7C-F0C0-4DB1-82E3-116C411A0342}" Description="TestLibrary" HelpDirectory="TARGETDIR" Language="0" MajorVersion="1" MinorVersion="0">
<Interface Id="{A13FF8B0-AC7C-33E5-B0F3-5366304512AC}" Name="_TestClass" ProxyStubClassId32="{00020424-0000-0000-C000-000000000046}" />
</TypeLib>
</File>
</Component>
</ComponentGroup>
</Fragment>
</Wix>
Main()中用于测试的添加行:
System.Diagnostics.Debug.WriteLine(new TestLibrary.TestClass().Add(5, 3));
我一直试图修复它两天,这让我疯了。似乎无法弄清楚它出错的地方,输出看起来很完美,类应该安装,但Signature程序无法启动。
提前致谢!
答案 0 :(得分:0)
我没有Phil所具有的错综复杂的COM知识,这就是我如何调试它。
启动干净的快照VM。 安装MSI。 运行注册表快照差异工具,例如InstallWatcher Pro。 运行regsvr32.exe your.dll 拍摄另一张快照并进行比较。 运行程序以确认regsvr32.exe修复了该问题。如果没有,请到别处寻找麻烦的来源。 滚动VM快照。
如果是这样,请分析差异并将其创建到.wxs并重建。冲洗并重复。