我正在使用log4net来记录我的应用程序中的事件/信息。我有一个接口IReader
,它由至少4个类实现,并且可以增长。每个类都有一个ReadBuffer()
方法,如果读取失败,我想记录错误。以下是一个类的方法定义:
public class IPortM350Connection : IReader
{
public void ReadBuffer()
{
try
{
this.AddToLog(iqBeaconLogType.Info, string.Format("Reader# {0} start reading.", SerialNumber));
while (IsConnected)
{
if (IportM350Obj != null && IportM350Obj.DataStream.IsOpen)
{
var data = IportM350Obj.GetBeaconTags();
var rampTagList = Utility.Identec350TagToTag(data);
if (rampTagList != null && rampTagList.Any())
{
var e = new RampTagReadEventArg(rampTagList);
// trigger Successful Tag read event
ReadMessage(this, e);
}
}
}
}
catch (ReaderTimeoutException ex)
{
this.AddToLog(iqBeaconLogType.Fatal, string.Format("Reader# {0} failed reading.", SerialNumber));
}
}
}
AddToLog扩展方法负责创建如下所示的日志。
public static void AddToLog(this object logObject, iqBeaconLogType logType, string message)
{
ILog log = LogManager.GetLogger(logObject.GetType());
var msg = string.Format("Event occured in : {0} at time {1}. Event Log : {2}",
logObject.GetType().ToString(),DateTime.Now.ToString(), message);
log.Fatal(msg);
}
当我设置配置文件以读取如下所示的类时,此方法正常工作:
<logger name="iqBeaconv7_1.ReaderLayer.Connection.IPortM350Connection" additivity="False">
<level value="ALL"/>
<appender-ref ref="RollingFileCompositeAppenderForIPort350Connection"/>
</logger>
但是,我认为如果我能够将IReader接口传递给记录器,那么我可以使用相同的文件记录所有类。将IPortM350Connection
替换为IReader
时,我没有输入日志条目。有没有人为界面编写配置文件,或者知道如何克服这个问题?
答案 0 :(得分:3)
您的AddToLog
方法正在创建一个记录器,其名称是派生类的名称(logObject.GetType()
)。您可能希望对所有派生类使用通用记录器,其名称为硬连线,或者是接口的名称(IReader
)。
我不完全确定我理解您要实现的目标,但您可以尝试将AddToLog方法更改为:
public static void AddToLog(this IReader logObject, iqBeaconLogType logType, string message)
{
ILog log = LogManager.GetLogger(typeof(IReader));
...
}
并将您的log4net配置设置为:
<logger name="iqBeaconv7_1.ReaderLayer.Connection.IReader" additivity="False">
...
</logger>