我试图让我们的OpenNMS仪表板显示我们的一个自定义监控组。 我已经编辑了observe-views.xml:
/etc/opennms
<?xml version="1.0" encoding="UTF-8"?>
<surveillance-view-configuration
xmlns:this="http://www.opennms.org/xsd/config/surveillance-views"
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
xsi:schemaLocation="http://www.opennms.org/xsd/config/surveillance-views http://www.opennms.org/xsd/config/surveillance-views.xsd"
default-view="default" >
<views >
<view name="default" refresh-seconds="300" >
<rows>
<row-def label="Routers" >
<category name="Routers"/>
</row-def>
<row-def label="Switches" >
<category name="Switches" />
</row-def>
<row-def label="Servers" >
<category name="Servers" />
</row-def>
<row-def label="Zinwave">
<category name="zinwave">
</row-def>
</rows>
<columns>
<column-def label="PROD" >
<category name="Production" />
</column-def>
<column-def label="TEST" >
<category name="Test" />
</column-def>
<column-def label="DEV" >
<category name="Development" />
</column-def>
</columns>
</view>
Zinwave行并没有显示在仪表板上。监视组zinwave存在并且其中有2个设备。没有定义自定义仪表板的用户,因此每个人都应该看到默认设置。
任何人都可以解释一下为什么我没有在我的仪表板上看到Zinwave组吗?
答案 0 :(得分:1)
你输了一个拼写错误:
<category name="zinwave">
这应该是:
<category name="zinwave" />
答案 1 :(得分:0)
请记住包含您希望在仪表板上显示的设备。 检查
管理 - &GT;管理监控类别 - &gt; zinwave并添加zinwave设备。
默认情况下,OpenNMS应插入您在Surveillance类别中创建的所有类别,但如果它不起作用,请尝试从Surveillance Categories中删除zinwave类别。然后重新创建它并再次添加设备。 (还要重启OpenNMS,它有帮助)。
请检查您的代码是否没有拼写错误。监视类别可以与类别不同,但如果可能的话我会使用相同的名称(以避免任何误解)。因此,请检查以下代码中是否需要大写z
<row-def label="Zinwave">
<category name="zinwave">
</row-def>