即使ADF已加载页面,WIA文档处理状态也会返回0

时间:2010-02-22 19:08:39

标签: vba wia image-scanner

我正在尝试使用VBA和Windows Image Acquisition库(WIA)从ADF进行扫描。我试图检查是否有ADF中加载的页面,所以我知道是否扫描另一页。这个功能似乎在Windows 7(我的开发机器)中运行良好,但在Windows XP(生产机器)中运行不正常。我知道MS在发布Vista时对WIA进行了一些更改,所以这可能是问题的根源。

我将包含整个函数调用,以期为我的问题提供足够的上下文。这个函数是我编写的类模块的一部分,因此它引用了类模块中的其他函数。为了简洁起见,我已将其他功能排除在外,但如果要求,我们很乐意发布这些功能。

'Windows Imaging Acquisition (WIA) Constants
Private Const wiaFormatBMP As String = "{B96B3CAB-0728-11D3-9D7B-0000F81EF32E}"
Private Const wiaFormatGIF As String = "{B96B3CB0-0728-11D3-9D7B-0000F81EF32E}"
Private Const wiaFormatJPEG As String = "{B96B3CAE-0728-11D3-9D7B-0000F81EF32E}"
Private Const wiaFormatPNG As String = "{B96B3CAF-0728-11D3-9D7B-0000F81EF32E}"
Private Const wiaFormatTIFF As String = "{B96B3CB1-0728-11D3-9D7B-0000F81EF32E}"

Public Function ScanPage(Optional ShowScanningWizard As Boolean = True, _
                         Optional OverWrite As Boolean = False, _
                         Optional AppendToTiff As Boolean = True, _
                         Optional DocType As scanDocType = scanAuto, _
                         Optional HRes As Integer = 150, _
                         Optional VRes As Integer = 150, _
                         Optional width As Double = 8.5, _
                         Optional height As Double = 11, _
                         Optional UseADF As Boolean = False) As Boolean
    'Windows Imaging Acquisition (WIA) Constants
Const ScannerDeviceType = 1
Const wiaIntentColor As Long = 1
Const wiaIntentGray As Long = 2
Const wiaIntentBlackWhite As Long = &H10004  '&H4 = IntentBlackWhite + &H10000 = Minimize Size   '&H20000'131072

Dim cd As Object    'WIA.CommonDialog
Dim dev As Object    'WIA.Device
Dim ip As Object    'WIA.ImageProcess
Dim Prop As Object    'WIA.Property
Dim img As Object    'WIA.ImageFile

Dim Intent As Long
Dim MorePages As Boolean

    On Error GoTo Err_ScanPage

    ScanPage = False

    'Verify scanned page can be saved
    If Len(m_sFileName) = 0 Then
        Err.Raise 5, , "Scan Aborted - No filename provided"
    ElseIf IsTiff And AppendToTiff Then
        'we're ok
    ElseIf m_bFileExists And Not OverWrite Then
        Err.Raise 58    'File already exists
    End If

    Set cd = CreateObject("WIA.CommonDialog")
    Set dev = cd.ShowSelectDevice(ScannerDeviceType)
    Set ip = CreateObject("WIA.ImageProcess")


    'Set up conversion filter
    ip.Filters.Add ip.FilterInfos("Convert").FilterID
    ip.Filters(ip.Filters.Count).Properties("FormatID").Value = FileFormat
    Select Case FileFormat
    Case wiaFormatJPEG
        ip.Filters(ip.Filters.Count).Properties("Quality").Value = 85
    Case wiaFormatTIFF
        'IP.Filters(IP.Filters.Count).Properties("Compression").Value = "CCITT4"
    End Select

    'Set intent for current document
    If DocType <> scanAuto Then m_eScanType = DocType
    If m_eScanType = scanDocument Then
        Intent = wiaIntentBlackWhite    'wiaIntentGray
    Else
        Intent = wiaIntentColor
    End If

    DoEvents
    If ShowScanningWizard Then
        Set img = cd.ShowAcquireImage(ScannerDeviceType, , , FileFormat)
    Else
        With dev.items(1)
            .Properties("Current Intent").Value = Intent
            .Properties("Horizontal Resolution").Value = HRes
            .Properties("Vertical Resolution").Value = VRes
            .Properties("Horizontal Extent").Value = HRes * width
            .Properties("Vertical Extent").Value = VRes * height
            If m_eScanType = scanDocument Then
                'Darken documents a bit so that handwriting is easier to see
                '   * Brightness is a value between -127 and +127
                '   * -45 was reached through trial and error and was tested on
                '     a CanoScan LiDE 20 flatbed scanner
                .Properties("Brightness").Value = -45
            End If

        End With
        On Error Resume Next
'        For Each Prop In dev.items(1).Properties
'            Debug.Print Prop.PropertyID, Prop.Name, Prop.Value
'        Next Prop
        'Scan the image
        If UseADF Then
            MorePages = True
            For Each Prop In dev.Properties
                Select Case Prop.PropertyID
                Case 3087 'Document Handling Select (1 = ADF)
                    MorePages = MorePages And (Prop.Value = 1)
                Case 3088 'Document Handling Status (1 = Page ready in ADF)
                    MorePages = MorePages And (Prop.Value = 1)
                End Select
            Next Prop
            If MorePages Then Set img = cd.ShowTransfer(dev.items(1), , True) ' dev.Items(1).Transfer()
        Else
            Set img = cd.ShowTransfer(dev.items(1), , True)
        End If
        If Err.Number <> 0 Then
            'User canceled the scan (most likely cause of error)
            Err.Clear
            ScanPage = False
            GoTo Exit_ScanPage
        End If
        On Error GoTo Err_ScanPage
    End If


    If img Is Nothing Then GoTo Exit_ScanPage
    'Convert to proper format
    Set img = ip.Apply(img)

    If IsTiff And AppendToTiff Then
        m_iNumPages = m_iNumPages + 1
        If m_iNumPages = 1 Then
            'ReDim Preserve throws an error if the array is currently empty
            ReDim m_sFNames(1 To 1)
        Else
            ReDim Preserve m_sFNames(1 To m_iNumPages)
        End If
        m_sFNames(m_iNumPages) = TempFileName(TempFilesPath, "tif")
        img.SaveFile m_sFNames(m_iNumPages)
        SaveToMultiTiff
        m_bFileExists = True
        ExtractPages
    Else
        If m_bFileExists And OverWrite Then Kill m_sFileName
        img.SaveFile m_sFileName
        m_iNumPages = 1
        m_bFileExists = True
    End If

    ScanPage = True

Exit_ScanPage:
    Exit Function
Err_ScanPage:
    Select Case Err.Number
    Case Else
        LogError Err.Number, Err.Description, "ScanPage", "clsScan"
    End Select
    Resume Exit_ScanPage
End Function

1 个答案:

答案 0 :(得分:0)

这在开发机器(Windows 7)而非生产机器(Windows XP)中起作用的原因与操作系统无关。差异实际上在驱动程序版本中。当我在开发机器上测试扫描仪时,它连接到Windows更新并下载了该扫描仪可用的最新驱动程序。 WinXP机器使用较旧的驱动程序用于同一扫描仪。通过将WinXP计算机上的扫描仪驱动程序更新到最新版本,它解决了我的问题。