正在传输工作流时,发生PE错误。我在工作流程中使用CE_Operations以外的自定义组件。
错误堆栈:
[FATAL 09 Apr 2014 15:25:21] Dispatcher got exception while doing query at April 9, 2014 3:25:21 PM GMT+05:30. Cause=[FNRPE2131090092E]The work space time stamp is stale
The work space has been updated by transfer, so the client workstation needs to load new workspaces and a new time stamp.
at filenet.pe.peorb.client.ORBUtility.mapServerException(ORBUtility.java:529)
at filenet.pe.peorb.client.ORBSession.executeRPC(ORBSession.java:1266)
at filenet.pe.peorb.client.ORBSession.fetch(ORBSession.java:2112)
at filenet.vw.api.VWQuery.fetch(VWQuery.java:653)
at filenet.vw.api.VWQueueQuery.dofetch(VWQueueQuery.java:429)
at filenet.vw.api.VWQuery.hasNext(VWQuery.java:768)
at filenet.vw.api.VWQueueQuery.hasNext(VWQueueQuery.java:461)
at filenet.vw.integrator.base.VWAdaptorControlEx$WorkflowDispatcher.run(VWAdaptorControlEx.java:359)
Root Cause:
[FNRPE2131090092E]The work space time stamp is stale
The work space has been updated by transfer, so the client workstation needs to load new workspaces and a new time stamp.
at filenet.jpe.server.common.IVWRuntimeServer.checkTimeStamps(IVWRuntimeServer.java:4754)
at filenet.jpe.server.common.IVWRuntimeServer.InitSession(IVWRuntimeServer.java:4064)
at filenet.jpe.rpc.orb.OrbRPC.<init>(OrbRPC.java:696)
at filenet.jpe.rpc.orb.ORBPERPC.orb_rpc_fetchQuery(ORBPERPC.java:911)
at filenet.pe.peorb.FileNet_PERPC.PERPCPOA._invoke(PERPCPOA.java:697)
at com.ibm.CORBA.poa.POAServerDelegate.dispatchToServant(POAServerDelegate.java:402)
at com.ibm.CORBA.poa.POAServerDelegate.internalDispatch(POAServerDelegate.java:334)
at com.ibm.CORBA.poa.POAServerDelegate.dispatch(POAServerDelegate.java:256)
at com.ibm.rmi.iiop.ORB.process(ORB.java:518)
at com.ibm.CORBA.iiop.ORB.process(ORB.java:1574)
at com.ibm.rmi.iiop.Connection.respondTo(Connection.java:2880)
at com.ibm.rmi.iiop.Connection.doWork(Connection.java:2753)
at com.ibm.rmi.iiop.WorkUnitImpl.doWork(WorkUnitImpl.java:63)
at com.ibm.rmi.iiop.WorkerThread.run(ThreadPoolImpl.java:202)
at java.lang.Thread.run(Thread.java:736)
如何解决此问题。谢谢!
答案 0 :(得分:0)
检查连接点的配置
确保它有效: 运行(安装目录)FileNet \ AE \ Router \ routercmd.bat 点击连接点,在右侧面板下的常规选项卡clic on buton“display work queue” - &GT;此操作尝试从AE到PE的连接,以检索工作队列的名称。 如果它工作,你的连接点应该工作 如果没有,请参阅(install dir)FileNet \ AE \ Router \下的vwtaskman.log以获取更多详细信息