我已搜索过此内容,但找不到任何针对此错误的内容或如何对其进行问题排查。
我们在代码中不同位置的不同计算机上间歇性地收到此错误。
以下是错误:
电脑1:
Application: propane.exe
Framework Version: v4.0.30319
Description: The process was terminated due to an unhandled exception.
Exception Info: System.Runtime.InteropServices.SEHException
Stack:
at SSS.Base.FastTrans.PrintReceipt.MakeString()
at SSS.Base.FastTrans.PrintReceipt.PrintIt()
at SSS.Base.FastTrans.CCPayment.PrintReceipt()
at SSS.Base.FastTrans.CCPayment.BottomPanelEnabled()
at SSS.Base.FastTrans.CCPayment.btnContinue_Click(System.Object, System.EventArgs)
at System.Windows.Forms.Control.OnClick(System.EventArgs)
at System.Windows.Forms.Button.OnClick(System.EventArgs)
at System.Windows.Forms.Button.OnMouseUp(System.Windows.Forms.MouseEventArgs)
at System.Windows.Forms.Control.WmMouseUp(System.Windows.Forms.Message ByRef, System.Windows.Forms.MouseButtons, Int32)
at System.Windows.Forms.Control.WndProc(System.Windows.Forms.Message ByRef)
at System.Windows.Forms.ButtonBase.WndProc(System.Windows.Forms.Message ByRef)
at System.Windows.Forms.Button.WndProc(System.Windows.Forms.Message ByRef)
at System.Windows.Forms.Control+ControlNativeWindow.OnMessage(System.Windows.Forms.Message ByRef)
at System.Windows.Forms.Control+ControlNativeWindow.WndProc(System.Windows.Forms.Message ByRef)
at System.Windows.Forms.NativeWindow.Callback(IntPtr, Int32, IntPtr, IntPtr)
at System.Windows.Forms.UnsafeNativeMethods.DispatchMessageW(MSG ByRef)
at System.Windows.Forms.Application+ComponentManager.System.Windows.Forms.UnsafeNativeMethods.IMsoComponentManager.FPushMessageLoop(IntPtr, Int32, Int32)
at System.Windows.Forms.Application+ThreadContext.RunMessageLoopInner(Int32, System.Windows.Forms.ApplicationContext)
at System.Windows.Forms.Application+ThreadContext.RunMessageLoop(Int32, System.Windows.Forms.ApplicationContext)
at System.Windows.Forms.Application.RunDialog(System.Windows.Forms.Form)
at System.Windows.Forms.Form.ShowDialog(System.Windows.Forms.IWin32Window)
at SSS.Common.BaseScreen.DynamicallyLoadScreen(System.String, System.String, SSS.Common.BaseScreen, Boolean)
at SSS.Common.BaseScreen.LoadNewScreen(ScreenOptions, SSS.Common.BaseScreen)
at SSS.Base.CustomerInquiry.CmdPaymentClick(System.Object, System.EventArgs)
at System.Windows.Forms.Control.OnClick(System.EventArgs)
at System.Windows.Forms.Button.OnClick(System.EventArgs)
at System.Windows.Forms.Button.OnMouseUp(System.Windows.Forms.MouseEventArgs)
at System.Windows.Forms.Control.WmMouseUp(System.Windows.Forms.Message ByRef, System.Windows.Forms.MouseButtons, Int32)
at System.Windows.Forms.Control.WndProc(System.Windows.Forms.Message ByRef)
at System.Windows.Forms.ButtonBase.WndProc(System.Windows.Forms.Message ByRef)
at System.Windows.Forms.Button.WndProc(System.Windows.Forms.Message ByRef)
at System.Windows.Forms.Control+ControlNativeWindow.OnMessage(System.Windows.Forms.Message ByRef)
at System.Windows.Forms.Control+ControlNativeWindow.WndProc(System.Windows.Forms.Message ByRef)
at System.Windows.Forms.NativeWindow.Callback(IntPtr, Int32, IntPtr, IntPtr)
at System.Windows.Forms.UnsafeNativeMethods.DispatchMessageW(MSG ByRef)
at System.Windows.Forms.Application+ComponentManager.System.Windows.Forms.UnsafeNativeMethods.IMsoComponentManager.FPushMessageLoop(IntPtr, Int32, Int32)
at System.Windows.Forms.Application+ThreadContext.RunMessageLoopInner(Int32, System.Windows.Forms.ApplicationContext)
at System.Windows.Forms.Application+ThreadContext.RunMessageLoop(Int32, System.Windows.Forms.ApplicationContext)
at Microsoft.VisualBasic.ApplicationServices.WindowsFormsApplicationBase.OnRun()
at Microsoft.VisualBasic.ApplicationServices.WindowsFormsApplicationBase.DoApplicationModel()
at Microsoft.VisualBasic.ApplicationServices.WindowsFormsApplicationBase.Run(System.String[])
at Sss.My.MyApplication.Main(System.String[])
电脑2:
Application: propane.exe
Framework Version: v4.0.30319
Description: The process was terminated due to an unhandled exception.
Exception Info: System.Runtime.InteropServices.SEHException
Stack:
at SSSObjectLibrary.VerifySalesAndService.VerifySASLibrary(System.String)
at SSS.Base.CustomerInquiry.CmdServiceOrderClick(System.Object, System.EventArgs)
at System.Windows.Forms.Control.OnClick(System.EventArgs)
at System.Windows.Forms.Button.OnClick(System.EventArgs)
at System.Windows.Forms.Button.OnMouseUp(System.Windows.Forms.MouseEventArgs)
at System.Windows.Forms.Control.WmMouseUp(System.Windows.Forms.Message ByRef, System.Windows.Forms.MouseButtons, Int32)
at System.Windows.Forms.Control.WndProc(System.Windows.Forms.Message ByRef)
at System.Windows.Forms.ButtonBase.WndProc(System.Windows.Forms.Message ByRef)
at System.Windows.Forms.Button.WndProc(System.Windows.Forms.Message ByRef)
at System.Windows.Forms.Control+ControlNativeWindow.OnMessage(System.Windows.Forms.Message ByRef)
at System.Windows.Forms.Control+ControlNativeWindow.WndProc(System.Windows.Forms.Message ByRef)
at System.Windows.Forms.NativeWindow.Callback(IntPtr, Int32, IntPtr, IntPtr)
at System.Windows.Forms.UnsafeNativeMethods.DispatchMessageW(MSG ByRef)
at System.Windows.Forms.Application+ComponentManager.System.Windows.Forms.UnsafeNativeMethods.IMsoComponentManager.FPushMessageLoop(IntPtr, Int32, Int32)
at System.Windows.Forms.Application+ThreadContext.RunMessageLoopInner(Int32, System.Windows.Forms.ApplicationContext)
at System.Windows.Forms.Application+ThreadContext.RunMessageLoop(Int32, System.Windows.Forms.ApplicationContext)
at Microsoft.VisualBasic.ApplicationServices.WindowsFormsApplicationBase.OnRun()
at Microsoft.VisualBasic.ApplicationServices.WindowsFormsApplicationBase.DoApplicationModel()
at Microsoft.VisualBasic.ApplicationServices.WindowsFormsApplicationBase.Run(System.String[])
at Sss.My.MyApplication.Main(System.String[])
这是两台计算机发出的第二条消息:
Faulting application name: propane.exe, version: 1.0.0.0, time stamp: 0x51ffc85e
Faulting module name: clr.dll, version: 4.0.30319.1008, time stamp: 0x517a1be7
Exception code: 0xc0000006
Fault offset: 0x0004a0c8
Faulting process id: 0xe80
Faulting application start time: 0x01cea9b048cb2d9d
Faulting application path: I:\RPG\vblib\propane.exe
Faulting module path: C:\Windows\Microsoft.NET\Framework\v4.0.30319\clr.dll
Report Id: c4a07f4d-1631-11e3-a5f3-1078d270d332
这些来自两个不同办公室的两台不同的计算机。我该如何解决这个问题?我们有一个“假设”的包装器来捕获应用程序中所有未处理的错误,并且此时它没有遗漏任何内容。这让我更加困惑于如何抓住所有这一切。
有什么建议吗?
答案 0 :(得分:6)
错误应用程序路径:I:\ RPG \ vblib \ propane.exe
这可能是异常细节中最重要的提示。异常代码(0xc0000006)是一个非常低级别的Windows错误,STATUS_IN_PAGE_ERROR,“由于I / O错误,所需的数据未被放入内存”。当操作系统需要从页面文件或内存映射文件中检索数据并且无法读取文件时,会发生此错误。
鞋子适合,驱动器号不常见,通常用于映射到网络共享。 .NET程序集作为内存映射文件加载,其中的元数据和MSIL根据抖动的要求动态加载,以生成程序集中方法的代码。
换句话说,客户使用的网络不够可靠。当网络连接断开时,程序崩溃。当然,除了强烈建议客户使用您应用的本地安装之外,您无能为力。 ClickOnce很适合。
答案 1 :(得分:0)
SEHException类处理从非托管代码抛出但尚未映射到另一个.NET Framework异常的SEH错误。所以你应该检查你的本机代码而不是C#代码