我是套接字编程的新手,我们在网络上有一个正在运行的MFC客户端应用程序,其套接字由于某种原因每天至少间歇性地断开连接一次。这不是网络的问题,因为其他网络应用程序运行正常。我注意到日志中的某些内容,即在套接字断开连接之前或多或少发生数据库错误10分钟。类似的东西:
DB ERROR: ADO Error 1 (s)
select l.LABOID, l.LABOCODE, l.LABOCREDATE, l.LABOTEXT, l.SHORTTEXT, l.LISACCOUNTINGMODE, l.ADDRESS1, l.ADDRESS2, l.POSTALCODE, l.CITY, l.STATE, l.COUNTRY, the . TELEPHON, l.FAX, l.EMAIL, l.TELEPHON2, l.NATIONALCODE, l.FIRSTITEMID, l.ALTERNATECODE, l.LABOSERVICEID, l.STARTVALIDDATE, l.ENDVALIDDATE, l.LOGUSERID, l.LOGDATE, b.DICBINARYID , b.OBJECTLINK, b.OBJECTTYPE, b.DICBINARYTYPE, b.BINARYDATE, b.BINARYMIMETYPE, b.BINARYSIZE, b.LOGUSERID, b.LOGDATE, b.BINARYOBJECT, (select count (*) from d DICT_LABO_TO_DEVICE Where l.LABOID = d.LABOID) as NB_DEVICES from DICT_LABORATORIES l, b DICT_BINARY_DATA Where l.ENDVALIDDATE is null and l.LABOCODE like '%%' and l.LABOID b.OBJECTLINK = (+) and b.DICBINARYTYPE (+) = 1 and b . OBJECTTYPE (+) = 7 AND LABOID IN (1) order by l.LABOCODE
ORA-00936: missing expression of
Error: 0x80040e14
在调试模式下,我发现线程仍在运行但是socket没有连接。我无法确定是什么导致它断开连接。 建议重新连接吗? 这是代码块:
if (m_pClientSocket->IsThreadStillRunning())
{
if(m_pClientSocket->m_boSocketConnected)
{
dwNbSent_L = *pdwBufferSize_P;
m_pClientSocket->Write(pbyBuffer_P, *pdwBufferSize_P);
iotResult_L = IOTRANS_RESULT_SUCCESS;
}
else
{
m_pobjSession->Write(MSG_ERROR,TRACE_LOW
,_T("%s Client socket is not connected")
,(LPCTSTR)m_strLastErrFunc);
iotResult_L = IOTRANS_RESULT_FAILED;
SetError(ERROR_SOCKET_NOT_CONNECTED, _T("Client socket is not connected"), m_strLastErrFunc);
}
}
任何人都可以给我一个快速入门或要检查的项目列表以防止这种情况发生吗?
答案 0 :(得分:1)
这可能是不网络错误。
Oracle DB无法解析SQL语句(导致错误ORA-00938),顶部的ADO层将Oracle错误转换为ADO错误0x80040e14,这意味着'该命令包含一个或多个错误。< / em>的”。
预计会在您的应用程序中出现错误。
你能做的是: