通过Tornado / Python重新启动和恢复ZigBee传感器的启动配置

时间:2012-10-22 13:48:12

标签: python tornado zigbee

我有一个问题。我有一个项目,一个家庭自动化系统,我必须通过接口向一些传感器,温度传感器,功率传感器,接触传感器等发送一些命令。

我已经完成了这个部分,我可以将开/关/切换命令发送到ZigBee传感器。我跟着this manual,这个命令在第196页描述。

我在项目的python中有这个部分来设置正确的数据包发送到传感器:

if command not in ['ON', 'OFF', 'TOGGLE']:
        raise tornado.web.HTTPError(404, "Unknown command: " + str(command))

    op_group = "70"
    op_code = "50"
    # *9999999999999999;70;50;;100260EB008060008000000D8#
    #                   70 50  100231AC00000000000008060008000101A9
    packet_meta = "*%s;%s;%s;%s;02%s%s600080000%s#"  # D8 i s the CRC who compute that?
    pkt_len = hextransform(16, 2)

    # Hexify the network ID
    netid = hextransform(int(nid), 16)
    # Hexify the sensor ID
    # TODO: - split sensor_id in ZTC sensor_id and endpoint!
    #       - ZTC sens ID is 2 bytes 
    #       - ZTC endpoint is 1 byte
#        sens_id = hextransform(int(sid) >> 8, 4)
#        end_point = hextransform(int(sid) & 0x0000FF, 2)


#        print("\nsens_id: '" + sens_id + "'\n")
#        print("\nendpoint: '" + end_point + "'\n")

    # TODO: - split sensor_id in ZTC sensor_id and clusterid!
    #       - ZTC sens ID is 2 bytes 
    #       - ZTC clusterid is 2 bytes
    sens_id = hextransform(int(sid) >> 16, 4)#elisa
    sens_id_little = invert2bytes(sens_id,0)
    cluster_id = hextransform(int(sid) & 0x00FFFF, 4)#elisa
    end_point = "08" #elisa

    if command == 'ON':
        cmd_data = "01"
    elif command == 'OFF':
        cmd_data = "00"
    elif command == 'TOGGLE':
        cmd_data = "02"

    packet = packet_meta % (netid, op_group, op_code, pkt_len, sens_id, end_point, cmd_data)
    packet = packet.upper()
    print("\t\t " + packet + "\n")

    ################ ELISA #########################################
    cmd_meta = "02%s000000000000080600080000%s" #elisa
    mycommand = cmd_meta % (sens_id_little, cmd_data) #elisa
    len_mycommand = len(mycommand)/2
    op_group_hex=0x70
    op_code_hex=0x50
    mynet_type ="ztc"

    cmdjson = packet2json(op_group_hex,op_code_hex, mycommand)
    #
    #
    #TODO : -write command into db  
    ts = datetime.datetime.now().isoformat()
    self.lock_tables("write", ['confcommands'])
self.db.execute("INSERT INTO confcommands (network_id, ntype, timestamp, command) \
                              VALUES (%s,%s,%s,%s)", nid, mynet_type, ts, cmdjson)
    self.unlock_tables();

现在,按照手册,我将添加restart命令,以重新启动传感器。然后还添加restore startup configuration命令。

所以我不知道手册中的这些命令在哪里。有几个。然后,我没有看到命令重启或恢复启动配置的明确值。如果对于开/关/切换有三个值(00,01,02),在这种情况下,手册不会说明要分配给cmd_data变量的值是什么,以创建发送到传感器的正确数据包。

我希望你能帮助我,因为我不知道在哪里寻找这个。非常感谢你。

2 个答案:

答案 0 :(得分:1)

我不知道ZigBee技术,但根据您的文档,您可以尝试发送名为APSME-RESET.RequestAPSME-REST.Confirm的APS消息以进行平台重置或NLME-Reset.Request和{{1} }用于网络管理器重置

答案 1 :(得分:1)

看起来这段代码使用的是ZigBee OnOff集群(0x0006),因为这些命令与您的代码正在进行的操作相匹配。由于ZigBee是小端,因此代码中的0600序列之一是群集ID。

基本群集(0x0000)支持单个命令0x00,它将设备重置为出厂默认值。请注意此命令,因为它可能导致设备离开网络并返回其默认网络设置。

我不知道您可以用来重启/重启设备的ZCL(ZigBee群集库)群集和命令。 ZigBee传感器可以运行多年而无需重启。

要详细了解ZCL群集和命令,您可以从ZigBee Cluster Library下载ZigBee Alliance

为什么您的设备需要重启传感器?