ComputedVerticalScrollBarVisibility如果使用绑定/转换器,则触发器不起作用

时间:2012-07-12 21:25:16

标签: c# wpf .net-3.5

这个问题与another SO question of mine非常相关,但这个问题更具体。请随意转到另一个问题以获取更多详细信息,但我应该提供您需要的所有内容。

我已经为我的listview实现了一个自定义样式,以便我可以使用以下内容访问滚动条属性(我删除了一些不相关的misc)

<Style x:Key="{x:Static GridView.GridViewScrollViewerStyleKey}" TargetType="ScrollViewer">
    <Setter Property="Template">
        <Setter.Value>
            <ControlTemplate TargetType="ScrollViewer">
                <Grid Background="{TemplateBinding Background}">
                    <DockPanel Margin="{TemplateBinding Padding}">
                        <ScrollViewer DockPanel.Dock="Top" Focusable="false">   
                    </DockPanel>
                    <ScrollBar Name="PART_HorizontalScrollBar" Orientation="Horizontal"  Grid.Row="1" Maximum="{TemplateBinding ScrollableWidth}" ViewportSize="{TemplateBinding ViewportWidth}" Value="{TemplateBinding HorizontalOffset}" Visibility="{TemplateBinding ComputedHorizontalScrollBarVisibility}"/>
                    <ScrollBar Name="PART_VerticalScrollBar" Grid.Column="1" Margin="20,0" Maximum="{TemplateBinding ScrollableHeight}" ViewportSize="{TemplateBinding ViewportHeight}" Value="{TemplateBinding VerticalOffset}" Visibility="{TemplateBinding ComputedVerticalScrollBarVisibility}"/>
                </Grid>
                <ControlTemplate.Triggers>
                    <Trigger Property="ComputedVerticalScrollBarVisibility" Value="Collapsed">
                        <Setter Property="Width">
                            <Setter.Value>
                                <Binding  
                                    ConverterParameter="400" 
                                    RelativeSource="{RelativeSource FindAncestor,AncestorType={x:Type ListView}}"
                             >
                                    <Binding.Converter>
                                        <Converters:ListViewColumnResizeConverter/>
                                    </Binding.Converter>
                                </Binding>
                            </Setter.Value>
                        </Setter>
                    </Trigger>
                    <Trigger Property="ComputedVerticalScrollBarVisibility" Value="Visible">
                        <Setter Property="Width">
                            <Setter.Value>
                                <Binding  
                                    ConverterParameter="500" 
                                    RelativeSource="{RelativeSource FindAncestor,AncestorType={x:Type ListView}}"
                             >
                                    <Binding.Converter>
                                        <Converters:ListViewColumnResizeConverter/>
                                    </Binding.Converter>
                                </Binding>
                            </Setter.Value>
                        </Setter>
                    </Trigger>
                </ControlTemplate.Triggers>
            </ControlTemplate>
        </Setter.Value>
    </Setter>
</Style>

请注意我拥有的两个触发器,一个用于Visible,另一个用于Collapsed。当我运行我的应用程序时,无论如何,我都会得到一个Visible,然后是Collapsed。我甚至延迟用计时器加载我的数据,但没有触发Visible是否有我遗漏的内容,或者这是Dependency Property无法正确触发的错误?

更新

所以,我注意到它的准系统版本正在工作(不使用绑定和转换器),所以我从我的代码中删除了它并使触发器只是更新背景颜色。并且,它有效,那么为什么添加绑定/转换器搞乱了触发器?

1 个答案:

答案 0 :(得分:1)

嗯,答案绝对没有帮助我,但似乎缓存了绑定的值。由于我的代码隐藏转换器更难以获得对Computed触发器的代码访问,我甚至没有使用返回值。但是,我继续为每个触发器绑定唯一的颜色值,一旦滚动条变得可见,我的代码就不再被击中,但是使用了初始调用的返回值。我必须承认,这对MS团队来说非常聪明,但对我来说却是一个绊脚石。如果用户具有可用于每个触发器的时间相关值,该怎么办?